Impact of Prosthesis-Patient Mismatch on Long-Term Survival in Patients With Small St Jude Medical Mechanical Prostheses in the Aortic Position

Author:

Mohty-Echahidi Dania1,Malouf Joseph F.1,Girard Steve E.1,Schaff Hartzell V.1,Grill Diane E.1,Enriquez-Sarano Maurice E.1,Miller Fletcher A.1

Affiliation:

1. From the Division of Cardiovascular Diseases (D.M.-E., J.F.M., S.E.G., M.E.E.-S., F.A.M.), the Division of Cardiovascular Surgery (H.V.S.), and the Division of Biostatistics (D.E.G.), Mayo Clinic, Rochester, Minn.

Abstract

Background— The impact of aortic prosthesis-patient mismatch (P-PtM) on long-term survival is unclear. Methods and Results— Between 1985 and 2000, 388 patients at Mayo Clinic in Rochester, Minn, underwent aortic valve replacement (AVR) with 19- or 21-mm St Jude Medical prostheses and had transthoracic echocardiography within 1 year after AVR. Mean age of patients was 62±13 years; 69% were female. Prosthesis effective orifice area (EOA) was derived from the continuity equation. P-PtM was classified as severe (indexed EOA ≤0.60 cm 2 /m 2 ), moderate (0.60 cm 2 /m 2 <indexed EOA≤0.85 cm 2 /m 2 ), or not hemodynamically significant (indexed EOA >0.85 cm 2 /m 2 ). P-PtM was severe in 66 patients (17%), moderate in 168 (43%), and not hemodynamically significant in 154 (40%). Patients with severe P-PtM had a significantly larger body surface area ( P <0.0001), higher mean gradient ( P <0.0001), lower preoperative ( P <0.0001) and postoperative ( P <0.0001) ejection fractions, and lower stroke volume ( P <0.0001) and more often received a 19-mm prosthesis ( P =0.0008) than patients with moderate or no hemodynamically significant mismatch. For patients with severe mismatch, 5-year survival rates (72±6%) and 8-year survival rates (41±8%) were significantly less than for patients with moderate mismatch (80±3% and 65±5%; P =0.026) or no hemodynamically significant mismatch (85±3% and 74±5%; P =0.002). On multivariate analysis after adjustment for other predictors of outcome, severe mismatch was associated with higher mortality (hazard ratio 2.18; 95% confidence interval 1.24 to 3.85; P =0.007) and higher incidence of congestive heart failure (hazard ratio 3.1; 95% confidence interval 1.3 to 7.4; P =0.009) than no hemodynamically significant mismatch. Conclusions— Severe P-PtM is an independent predictor of higher long-term mortality and congestive heart failure in patients with small St Jude Medical aortic valve prostheses. For patients undergoing AVR who are at risk of severe mismatch, every effort should be made to use a larger prosthesis or to consider a prosthesis with a larger EOA.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3