A fourth criterion for transient entrainment: the electrogram equivalent of progressive fusion.

Author:

Henthorn R W1,Okumura K1,Olshansky B1,Plumb V J1,Hess P G1,Waldo A L1

Affiliation:

1. Department of Medicine, Case Western Reserve University, Cleveland, OH.

Abstract

Prior data pertaining to transient entrainment and associated phenomena have been best explained by pacing capture of a reentrant circuit. On this basis, we hypothesized that rapid pacing from a single site of two different constant pacing rates could constantly capture an appropriately selected bipolar electrogram recording site from one direction with a constant stimulus-to-electrogram interval during pacing at one rate, yet be constantly captured from another direction with a different constant stimulus-to-electrogram interval when pacing at a different constant pacing rate. To test this hypothesis, we studied a group of patients, each with a representative tachycardia (ventricular tachycardia, circus-movement tachycardia involving an atrioventricular bypass pathway, atrial tachycardia, and atrial flutter). For each tachycardia, pacing was performed from a single site for at least two different constant rates faster than the spontaneous rate of the tachycardia. We observed in these patients that a local bipolar recording site was constantly captured from different directions at two different pacing rates without interrupting the tachycardia at pacing termination. The evidence that the same site was captured from a different direction at two different pacing rates was supported by demonstrating a change in conduction time to that site associated with a change in the bipolar electrogram morphology at that site when comparing pacing at each rate. The mean conduction time (stimulus-to-recording site electrogram interval) was 319 +/- 69 msec while pacing at a mean cycle length of 265 +/- 50 msec, yet only 81 +/- 38 msec while pacing at a second mean cycle length of 233 +/- 51 msec, a mean change in conduction time of 238 +/- 56 msec. Remarkably, the faster pacing rate resulted in a shorter conduction time. The fact that the same electrode recording site was activated from different directions without interruption of the spontaneous tachycardia at pacing termination is difficult to explain on any mechanistic basis other than reentry. Also, these changes in conduction time and electrogram morphology occurred in parallel with the demonstration of progressive fusion beats on the electrocardiogram, the latter being an established criterion for transient entrainment.(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 128 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3