Further observations on transient entrainment: importance of pacing site and properties of the components of the reentry circuit.

Author:

Okumura K,Henthorn R W,Epstein A E,Plumb V J,Waldo A L

Abstract

Transient entrainment of circus-movement tachycardia utilizing an atrioventricular (AV) bypass pathway was studied in 13 patients (nine with the orthodromic form, two with the antidromic form, and two with both the orthodromic and antidromic forms). All patients had a left-sided AV bypass pathway. Pacing at selected rates faster than the spontaneous rate was performed during the tachycardia at a site proximal or distal to the AV node, an area of slow conduction within the reentry loop. Rapid pacing from a site proximal to the AV node (from the right atrium during the orthodromic form of the arrhythmia or the right ventricle during the antidromic form of the arrhythmia) always demonstrated at least one of the three entrainment criteria: constant fusion beats except for the last captured beat, which was entrained but not fused (first criterion); progressive fusion (second criterion); localized conduction block to a site(s) for 1 paced beat associated with interruption of the tachycardia followed by activation of that site(s) by the next paced beat from a different direction and with a shorter conduction time (third criterion). In contrast, rapid pacing from a site distal to the AV node (from the right ventricle during the orthodromic form of the arrhythmia, or the right atrium during the antidromic form of the arrhythmia) transiently entrained the tachycardia, but never demonstrated any entrainment criteria because the antidromic wave front from the pacing impulse always blocked in the AV node (concealed entrainment). We conclude that the location of the pacing site relative to the components of a reentry loop is critical to the demonstration of the criteria of transient entrainment; i.e., if it is proximal to an area of slow conduction and/or unidirectional block within a reentry loop, transient entrainment should be demonstrable, but if it is distal, it will not be demonstrable.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3