Rapid Diagnosis of Human Herpesvirus 6 Infection by a Novel DNA Amplification Method, Loop-Mediated Isothermal Amplification

Author:

Ihira Masaru1,Yoshikawa Tetsushi2,Enomoto Yoshihiko2,Akimoto Shiho2,Ohashi Masahiro2,Suga Sadao2,Nishimura Naoko3,Ozaki Takao3,Nishiyama Yukihiro4,Notomi Tsugunori5,Ohta Yoshinori5,Asano Yoshizo2

Affiliation:

1. Department of Medical Information Technology, Fujita Health University College

2. Department of Pediatrics, Showa Hospital, Konan, Aichi

3. Department of Pediatrics, Fujita Health University School of Medicine, Toyoake

4. Department of Virology, Nagoya University Graduate School of Medicine, Nagoya

5. Eiken Chemical Co., Ltd., Shimoishigami, Ohtawara, Tochigi, Japan

Abstract

ABSTRACT A novel nucleic acid amplification method, termed loop-mediated isothermal amplification (LAMP), which amplifies DNA with high specificity, efficiency, and rapidity under isothermal conditions, may be a valuable tool for the rapid detection of infectious agents. LAMP was developed for human herpesvirus 6 (HHV-6), and its reliability was evaluated in this study. Although LAMP products were detected in HHV-6 B and HHV-6 A DNA, they were not detected in HHV-7 and human cytomegalovirus DNA. The sensitivity of the original HHV-6 LAMP protocol was 50 copies/tube. In order to increase the method's sensitivity, HHV-6 LAMP was modified by increasing the primer concentration. As a result of the modification, sensitivity increased to 25 copies/tube. After these initial validation studies, 13 patients with fever were tested for HHV-6 by viral isolation, serological analysis, and HHV-6 LAMP. In three of the eight patients with primary HHV-6 infection, HHV-6 DNA was detected in whole blood by the original HHV-6 LAMP protocol in not only the acute phase but also the convalescent phase. HHV-6 DNA was detected by modified HHV-6 LAMP in all eight plasma samples collected in the acute phase; however, no HHV-6 DNA was detected in plasma samples collected in the convalescent phase. Although HHV-6 DNA was detected in both the acute and convalescent phases of whole-blood samples in patients with past HHV-6 infection, it was not detected in plasma samples that did not contain latent viral DNA. Thus, detection of HHV-6 DNA in plasma by using this modified HHV-6 LAMP protocol is appropriate for diagnosis of active HHV-6 infection.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3