Biomechanical evaluation of the hybrid pedicle screw—cortical bone trajectory technique in transforaminal lumbar interbody fusion to adjacent segment degeneration—finite element analysis

Author:

Zhang Rui,Kahaer Alafate,Niu Hanqian,Wang Jingwen,Jumahan Ayididaer,Qiu Yanning,Rexiti Paerhati,Guo Hailong

Abstract

Abstract Background Transforaminal lumbar interbody fusion is an effective surgical treatment of intervertebral disk herniation. However, its clinical efficacy for adjacent segment disk degeneration (ASDD) after hybrid bilateral pedicle screw - bilateral cortical screw (pedicle screw at L4 and cortical bone trajectory screw at L5) and hybrid bilateral cortical screw - bilateral pedicle screw (bilateral cortical screw at L4 and bilateral pedicle screw at L5) remains undiscovered. Therefore, the aim of this study is to evaluate the effect of the hybrid bilateral pedicle screw - bilateral cortical screw and hybrid bilateral cortical screw - bilateral pedicle screw on the adjacent segment via a 3-dimensional (3D) finite element (FE) analysis. Methods Four human cadaveric lumbar spine specimens were provided by the anatomy teaching and research department of Xinjiang Medical University. Four finite element models of L1-S1 lumbar spine segment were generated. For each of these, four lumbar transforaminal lumbar interbody fusion models at L4-L5 segment with the following instruments were created: hybrid bilateral pedicle screw - bilateral cortical screw, bilateral cortical screw - bilateral cortical screw (bilateral cortical screw at both L4 and L5 segments), bilateral pedicle screw - bilateral pedicle screw (bilateral pedicle screw at both L4 and L5 segments), and hybrid bilateral cortical screw - bilateral pedicle screw. A 400-N compressive load with 7.5 Nm moments was applied for the simulation of flexion, extension, lateral bending, and rotation. The range of motion of L3-L4 and L5-S1 segments and von Mises stress of the intervertebral disc at the adjacent segment were compared. Results Hybrid bilateral pedicle screw - bilateral cortical screw has the lowest range of motion at L3-L4 segment in flexion, extension, and lateral bending, and the highest disc stress in all motions, while the range of motion at L5-S1 segment and disc stress was lower than bilateral pedicle screw - bilateral pedicle screw in flexion, extension, and lateral bending, and higher than bilateral cortical screw - bilateral cortical screw in all motions. The range of motion of hybrid bilateral cortical screw - bilateral pedicle screw at L3-L4 segment was lower than bilateral pedicle screw - bilateral pedicle screw and higher than bilateral cortical screw - bilateral cortical screw in flexion, extension, and lateral bending, and the range of motion at L5-S1 segment was higher than bilateral pedicle screw - bilateral pedicle screw in flexion, lateral bending, and axial rotation. The disc stress at L3-L4 segment was lowest and more dispersed in all motions, and the disc stress at L5-S1 segment was higher than bilateral pedicle screw - bilateral pedicle screw in lateral bending and axial rotation, but more dispersed. Conclusion Hybrid bilateral cortical screw - bilateral pedicle screw decreases the impact on adjacent segments after spinal fusion, reduces the iatrogenic injury to the paravertebral tissues, and provides throughout decompression of the lateral recess.

Funder

College Students’ Innovative Entrepreneurial Training Plan Program

central-class public welfare research institute project of Chinese Academy of Medical Sciences

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3