Author:
Li Ping,Xiu Guohua,Mata Vera G.,Grande Carlos A.,Rodrigues Alirio E.
Abstract
AbstractStreamline Direct CST I is a new type of ion exchanger with multi‐modal functional groups, specially designed for an expanded bed adsorption (EBA) process, which can capture directly the proteins from the high ionic strength feedstocks with a high binding capacity. In this study, an experimental study is carried out for two‐component proteins (BSA and myoglobin) competitive adsorption and desorption in an expanded bed packed with Streamline Direct CST I. Based on the measurements of the single‐ and two‐component bovine serum albumin (BSA)/myoglobin adsorption isotherm on Streamline Direct CST I, the binding and elution conditions for the whole EBA process are selected; and then frontal analysis for a longer timescale and column displacement experiments in a fixed bed (XK16/20 column) are carried out to evaluate the two‐component proteins (BSA and myoglobin) competitive adsorption and displacement on Streamline Direct CST I. Finally, the feasibility of capturing both BSA and myoglobin by an expanded bed packed with Streamline Direct CST I is addressed in a Streamline 50 column packed with 300 mL Streamline Direct CST I. © 2006 Wiley Periodicals, Inc.
Cited by
33 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献