Modified Percutaneous Lumbar Foraminoplasty and Percutaneous Endoscopic Lumbar Discectomy: Instrument Design, Technique Notes, and 5 Years Follow-up

Author:

Li Zhen-zhou1

Affiliation:

1. The First Affiliated Hospital of Chinese PLA’s General Hospital Beijing, China

Abstract

Background: Conventional percutaneous endoscopic lumbar discectomy (PELD) with an “insideoutside” technique has 4.3% – 10.3% surgical failure rate, especially in central herniated discs (HDs), migrated HDs, and axillary type HDs. PELD with foraminoplasty has been used for complex HDs. Percutaneous lumbar foraminoplasty (PLF), which is performed with a trephine or bone reamer introduced over a guidewire without a protective working cannula in the original Tessys technique, can quickly cut the hypertrophied bony structure under fluoroscopic guidance, and risk injury to the exiting and traversing nerve roots. Study Design: A prospective cohort study. Setting: Hospital and outpatient surgical center. Objective: To evaluate the outcome and safety of modified PLF-PELD with a specially designed instrument for complex uncontained lumbar HDs. Method: From April of 2007 to April of 2009, 148 patients with uncontained lumbar HDs were treated with modified PLF-PELD. Magnetic resonance imaging (MRI) checkup was performed the next morning after the operation. Outcomes of symptoms were evaluated by follow-up interviews at 3 months, 6 months, one year, and 5 years after surgery. Low back pain and leg pain were measured by visual analog scale (VAS) score (1 – 100). Functional outcomes were assessed by using the Oswestry Disability Index (ODI) and modified MacNab criteria. Result: Follow-up data were obtained from 134 cases, including 14 cases on L3-4, 78 cases on L4-5, and 42 cases on L5-S1. One hundred-eight cases were prolapse type, while 26 cases were sequestration type. Pre-operative symptoms and deficits included nerve root dermatome hypoesthesia in 98 patients (73%), nerve root myotome muscle weakness in 32 patients (23%), and weakening or disappearance of tendon reflex in 43 patients (32%). No case required conversion to an open procedure during the surgery. Low back pain and leg pain were significantly relieved immediately after surgery in all patients. MRI examination showed adequate removal of HD in all patients. VAS scores and ODI values were significantly lower at all time points after surgery than before surgery. The percentage of pain relief in leg pain was significantly higher than that in low back pain (P < 0.01). But there was no significant correlation between duration of the preoperative symptoms and the percentage of pain relief. MacNab scores at 5 years after surgery were obtained from 134 patients. Seventy-five cases were rated “excellent”; 49 were rated “good,” Five patients experienced heavier low back pain, thus being classified as “fair.” Five cases with recurrence were rated “poor.” Preoperative and postoperative (5 years follow-up) related nerve root function status was compared. Sensation and muscle strength recovered significantly (P < 0.01), while tendon reflex was not changed (P = 0.782). No patients had infections. Five patients were complicated with dysesthesia in distribution of the exiting nerve that was all operated at L5-S1. Complaints were reduced one week after treatment with medium frequency pulse electrotherapy. Five cases required a revision surgery after recurrence. Limitations: This is an observational clinical case series study without comparison. Cohort Study Modified Percutaneous Lumbar Foraminoplasty and Percutaneous Endoscopic Lumbar Discectomy: Instrument Design, Technique Notes, and 5 Years Follow-up From: The First Affiliated Hospital of Chinese PLA’s General Hospital Beijing, China Address Correspondence: Zhen-zhou Li, M.D. Associate Chief Surgeon The First Affiliated Hospital of Chinese PLA’s General Hospital, Department of Orthopedic Surgery No. 51, Fucheng Road Haidian district Beijing, Beijing 100048 China 86 1068989322 E-mail: dr_lizhenzhou@163.com Disclaimer: There was no external funding in the preparation of this manuscript. Conflict of interest: Each author certifies that he or she, or a member of his or her immediate family, has no commercial association (i.e., consultancies, stock ownership, equity interest, patent/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted manuscript. Manuscript received: 08-10-2015 Revised manuscript received: 12-28-2015 Accepted for publication: 03-28-2015 Free full manuscript: www.painphysicianjournal. com Zhen-zhou Li, MD, Shu-xun Hou, MD, Wei-lin Shang, MD, Ke-ran Song, MD, and Hong-liang Zhao, MD www.painphysicianjournal.com Pain Physician 2017; 20:E85-E98 • ISSN 2150-1149 Conclusion: Modified PLF-PELD with a specially designed instrument is a less invasive, effective and safe surgery for complex uncontained lumbar DH. Key words: Lumbar disc herniation, minimally invasive treatment, foraminoplasty, percutaneous endoscopic lumbar discectomy

Publisher

American Society of Interventional Pain Physicians

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3