Measured Impact of a Rooftop Photovoltaic System

Author:

Fanney A. Hunter1,Weise Eric R.1,Henderson Kenneth R.1

Affiliation:

1. National Institute of Standards and Technology, 100 Bureau Drive, MS 8632, Gaithersburg, MD 20899-8632

Abstract

A 35-kW rooftop photovoltaic (PV) system has been installed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland. The system, located on the flat roof that connects NIST’s Administration Building to its adjoining conference and cafeteria facilities, produced NIST’s first site-generated renewable energy on September 14, 2001. In addition to providing electrical energy and reducing monthly peak electrical loads, the rear surface of each module is laminated to 51 mm of extruded polystyrene enhancing the thermal performance of the roof. A unique ballast system secures the photovoltaic system, eliminating the need for roof penetrations. An instrumentation and data acquisition package was installed to record the ambient temperature, wind speed, solar radiation, and the electrical energy delivered to the grid. Additional solar radiation instruments were installed after determining that the original solar radiation sensor was influenced by reflections from the south-facing wall of the Administration Building’s tower. NIST’s electric utility billing schedule includes energy and peak demand charges. The generation charges vary significantly depending upon the time interval—off-peak, intermediate, and on-peak—during which the energy is consumed. The schedule is divided into summer billing months (June–October) and winter billing months (November–May). During the winter billing months, the distribution, transmission, and generation peak demand charges are based on the greatest power demand imposed by the site on the grid. During the summer billing months, an additional demand charge is imposed to capture electrical demand during the on-peak time interval. This paper summarizes the monthly and annual measured performance of the photovoltaic system. The monthly energy produced by the system is tabulated. The system has provided 35676 kWh of electrical energy during its first year of operation. Conversion efficiencies—computed using solar radiation measurements from a single photovoltaic cell radiation sensor, four thermopile-based radiation sensors located around the perimeter of the photovoltaic array, and a remotely located thermopile-based radiation sensor—are presented. Annual conversion efficiencies of 10.8%, 8.8%, and 7.4% were achieved using cell, module, and foot print areas, respectively. Using the electric utility’s rate schedule, the monetary savings credited to the photovoltaic system is determined by combining the cost of the displaced energy with the reduction in peak demand charges attributable to the photovoltaic system. During its first year of operation, the system has saved $2678 with savings in demand charges, essentially equivalent to savings as a result of displaced energy. Finally, using utility provided data and the Environmental Protection Agency’s (EPA) Environmental Benefits Calculator, estimates are made of the avoided emissions of the photovoltaic system over its projected life span.

Publisher

ASME International

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

Reference7 articles.

1. Neff, D.E., and Bienkiewicz, B., [2000], “Wind Tunnel Study of PowerGuard® RT Arrays,” Final Report, PowerLight Corp., Berkeley, CA.

2. American Society of Civil Engineers, 7-98, 2000, “Minimum Design Loads for Buildings and Other Structures,” Revision of ANSI/ASCE7-95.

3. Shell Solar Product Information Sheet, Shell SP150-P, Photovoltaic Solar Module, V2/SP150-P/05/02/US.

4. Fanney, A.H., Dougherty, B.P., and Davis, M.W., 2001, “Building Integrated Photovoltaic Test Facility,” ASME J. Sol. Energy Eng., 123(3), pp. 194–199.

5. Kuklewicz, M., 2002, Personal communication.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ballast-Supported Foundation Designs for Low-Cost Open-Source Solar Photovoltaic Racking;Designs;2024-02-04

2. Electrical and Electroluminescence Evaluation of 17 Year Old Monocrystalline Silicon Building Integrated Photovoltaic Modules;2023 IEEE 50th Photovoltaic Specialists Conference (PVSC);2023-06-11

3. Approaches for biological and biomimetic energy conversion;Proceedings of the National Academy of Sciences;2006-03-27

4. Photovoltaics literature survey (No. 26);Progress in Photovoltaics: Research and Applications;2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3