Affiliation:
1. University of British Columbia, Vancouver, BC, Canada
Abstract
A Computational Fluid Dynamics simulation of near-field cough and sneeze droplet dispersion and heat and mass transfer is developed. In this study various sources of variability in cough and sneeze processes are considered. These are variations in injection volume (0.5l, 2.5l, and 5.0l) and ambient relative humidity (20%, 40% and 60%). There are a total of 9 simulations for coughs and sneezes in a quiescent background. A large ensemble (5000) of droplets are tracked with diameters in the range 1–500micron. Evaporation and dispersion are predicted as a function of droplet size. Generally, fine droplets evaporate faster than large droplets. Higher relative humidities slow the evaporation process. Larger droplets have greater axial penetration. They also exhibit greater vertical drop due to the effect of gravity. Sideway penetration is increased by higher injection volumes. The buoyancy effect due to thermal energy of the injection is very weak, at least for the 10-second computation duration.
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献