Affiliation:
1. Technische Universität Dresden, Dresden, Germany
Abstract
Passive systems like natural circulation (NC) loops can offer reliable and cost efficient alternatives to common active systems for decay heat removal in nuclear power plants. During the transition between stable single and stable two phase flows, instabilities e. g. flashing and geysering may occur in the riser due to low system pressure and saturation temperature conditions. These instabilities may cause severe stress to the system components. This paper presented some results of the study on the decay heat removal system based on natural circulation, performed on the open loop NC test facility GENEVA, built at TU Dresden in 2013. 16 probes were used to determine void fraction along the riser on nine different levels in high time and spatial resolution, and stability maps was created for riser with inner diameters of 20 mm and 38 mm and up to 85 kW evaporator power.
Publisher
American Society of Mechanical Engineers
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献