A Cellular Solid Criterion for Predicting the Axial-Shear Failure Properties of Bovine Trabecular Bone

Author:

Fenech C. M.1,Keaveny T. M.2

Affiliation:

1. Orthopædic Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, CA 94720

2. Orthopædic Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, CA 94720; Department of Orthopædic Surgery, University of California, San Francisco, CA 94143

Abstract

In a long-term effort to develop a complete multi-axial failure criterion for human trabecular bone, the overall goal of this study was to compare the ability of a simple cellular solid mechanistic criterion versus the Tsai–Wu, Principal Strain, and von Mises phenomenological criteria—all normalized to minimize effects of interspecimen heterogeneity of strength—to predict the on-axis axial-shear failure properties of bovine trabecular bone. The Cellular Solid criterion that was developed here assumed that vertical trabeculae failed due to a linear superposition of axial compression/tension and bending stresses, induced by the apparent level axial and shear loading, respectively. Twenty-seven bovine tibial trabecular bone specimens were destructively tested on-axis without end artifacts, loaded either in combined tension-torsion (n = 10), compression-torsion (n = 11), or uniaxially (n = 6). For compression-shear, the mean (± S.D.) percentage errors between measured values and criterion predictions were 7.7 ± 12.6 percent, 19.7 ± 23.2 percent, 22.8 ± 18.9 percent, and 82.4 ± 64.5 percent for the Cellular Solid, Tsai–Wu, Principal Strain, and von Mises criteria, respectively; corresponding mean errors for tension-shear were –5.2 ± 11.8 percent, 14.3 ± 12.5 percent, 6.9 ± 7.6 percent, and 57.7 ± 46.3 percent. Statistical analysis indicated that the Cellular Solid criterion was the best performer for compression-shear, and performed as well as the Principal Strain criterion for tension-shear. These data should substantially improve the ability to predict axial-shear failure of dense trabecular bone. More importantly, the results firmly establish the importance of cellular solid analysis for understanding and predicting the multiaxial failure behavior of trabecular bone.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 66 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Scaphoid numerical simulation of the critical loading until fracture;Journal of the Mechanical Behavior of Biomedical Materials;2023-12

2. A review on prediction of bone fracture using LEFM;Forces in Mechanics;2023-02

3. Effects of assessing the bone remodeling process in biomechanical finite element stability evaluations of dental implants;Computer Methods and Programs in Biomedicine;2022-06

4. Shear behavior of human skull bones;Journal of the Mechanical Behavior of Biomedical Materials;2021-04

5. Comparative cranial biomechanics in two lizard species: impact of variation in cranial design;Journal of Experimental Biology;2021-03-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3