In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants

Author:

Santana Luís Carlos Leal1ORCID,Idogava Henrique Takashi2,De Foggi Camila Cristina3,Guastaldi Fernando Pozzi Semeghini4,Noritomi Pedro Yoshito5,dos Reis Barbara Araújo6,Vaz Luis Geraldo6

Affiliation:

1. Department of Diagnosis and Surgery, São Paulo State University (Unesp), School of Dentistry , Araraquara, São Paulo 14801-385, Brazil

2. Department of Mechanical Engineering, Engineering School of São Carlos, University of São Paulo (USP) , São Carlos, São Paulo 13566-590, Brazil

3. Department of Conservative Dentistry, Federal University of Rio Grande do Sul (UFRGS), Dental School , Porto Alegre, Rio Grande do Sul 90035-003, Brazil

4. Department of Oral and Maxillofacial Surgery, Massachusetts General Hospital (MGH), Harvard School of Dental Medicine , Boston, MA 02114

5. 3D Technology Core (NT3D) at Renato Archer Information Technology Center , Campinas, São Paulo 13069-901, Brazil

6. Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), School of Dentistry , Araraquara, São Paulo 14801-385, Brazil

Abstract

AbstractShort dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference64 articles.

1. All-On-Four” Immediate-Function Concept With Brånemark System Implants for Completely Edentulous Mandibles: A Retrospective Clinical Study;Clin. Implant. Dent. Relat. Res.,2003

2. The All-On-Four Immediate Function Treatment Concept With NobelActive Implants: A Retrospective Study;J. Oral Implantol.,2011

3. All-On-4(R) Treatment Concept for the Rehabilitation of the Completely Edentulous Mandible: A 7-Year Clinical and 5-Year Radiographic Retrospective Case Series With Risk Assessment for Implant Failure and Marginal Bone Level;Clin. Implant. Dent. Relat. Res.,2015

4. The All-on-Four Treatment Concept: A Systematic Review;Clin. Implant. Dent. Relat. Res.,2014

5. The Influence of Cantilever Length and Implant Inclination on Stress Distribution in Maxillary Implant-Supported Fixed Dentures;J. Prosthet. Dent.,2011