Normal Contact of Elastic Spheres With Two Elastic Layers as a Model of Joint Articulation

Author:

Eberhardt A. W.1,Lewis J. L.2,Keer L. M.3

Affiliation:

1. Department of Mechanical Engineering, University of Alabama at Birmingham, Birmingham, AL 32548

2. Department of Orthopaedic Surgery, University of Minnesota, Minneapolis, MN 55455

3. Department of Civil Engineering, Northwestern University, Evanston, IL 60208

Abstract

An analytical model of two elastic spheres with two elastic layers in normal, frictionless contact is developed which simulates contact of articulating joints, and allows for the calculation of stresses and displacements in the layered region of contact. Using various layer/layer/substrate combinations, the effects of variations in layer and substrate properties are determined in relation to the occurrence of tensile and shear stresses as the source of crack initiation in joint cartilage and bone. Vertical cracking at the cartilage surface and horizontal splitting at the tidemark have been observed in joints with primary osteoarthritis. Deep vertical cracks in the calcified cartilage and underlying bone have been observed in blunt trauma experiments. The current model shows that cartilage stresses for a particular system are a function of the ratio of contact radius to total layer thickness (a/h). Surface tension, which is observed for a/h small, is alleviated as a/h is increased due to increased load, softening and/or thinning of the cartilage layer. Decreases in a/h due to cartilage stiffening lead to increased global compressive stresses and increased incidence of surface tension, consistent with impact-induced surface cracks. Cartilage stresses are not significantly affected by variations in stiffness of the underlying material. Tensile radial strains in the cartilage layer approach one-third of the normal compressive strains, and increase significantly with cartilage softening. For cases where the middle layer stiffness exceeds that of the underlying substrate, tensile stresses occur at the base of the middle layer, consistent with impact induced cracks in the zone of calcified cartilage and subchondral bone. The presence of the superficial tangential zone appears to have little effect on underlying cartilage stresses.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 68 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3