Exergy Analysis of Data Center Thermal Management Systems

Author:

Shah Amip J.1,Carey Van P.1,Bash Cullen E.2,Patel Chandrakant D.2

Affiliation:

1. Department of Mechanical Engineering, University of California, Berkeley, CA 94720-1740

2. Hewlett Packard Laboratories, 1501 Page Mill Road, M/S 1183, Palo Alto, CA 94304-1126

Abstract

The modeling of recirculation patterns in air-cooled data centers is of interest to ensure adequate thermal management of computer racks at increased heat densities. Most metrics that describe recirculation are based exclusively on temperature inside the data center, and therefore fail to provide adequate information regarding the energy efficiency of the thermal infrastructure. This paper addresses this limitation through an exergy analysis of the data center thermal management system. The approach recognizes that the mixing of hot and cold streams in the data center airspace is an irreversible process and must therefore lead to a loss of exergy. Experimental validation in a test data center confirms that such an exergy-based characterization in the cold aisle reflects the same recirculation trends as suggested by traditional temperature-based metrics. Further, by extending the exergy-based model to include irreversibilities from other components of the thermal architecture, it becomes possible to quantify the amount of available energy supplied to the cooling system that is being utilized for thermal management purposes. The energy efficiency of the entire data center cooling system can then be collapsed into the single metric of net exergy loss. When evaluated against a ground state of the external ambience, this metric enables an estimate of how much of the energy emitted into the environment could potentially be harnessed in the form of useful work. Thus, this paper successfully demonstrates that the proposed exergy-based approach can provide a foundation upon which the data center cooling system can be simultaneously evaluated for thermal manageability and energy efficiency.

Publisher

ASME International

Subject

Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science

Reference54 articles.

1. Smart Chip, System and Data Center Enabled by Advanced Flexible Cooling Resources;Patel

2. Thermal Considerations in Cooling Large Scale High Computer Density Data Centers;Patel

3. Patel, C. D., and Shah, A. J., 2005, “Cost Model for Planning, Development and Operation of a Data Center,” Hewlett Packard Laboratories, Palo Alto, CA, Technical Report No. HPL-2005-107R1.

4. Sullivan, R. F. , 2003, “Alternating Cold and Hot Aisles Provides More Reliable Cooling for Server Farms,” White Paper by The Uptime Institute, Santa Fe, NM.

5. American Power Conversion, 2003, “Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms,” White Paper 49 by American Power Conversion, Washington, DC.

Cited by 47 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3