Extraction of Quasi-Linear Viscoelastic Parameters for Lower Limb Soft Tissues From Manual Indentation Experiment

Author:

Zheng Y. P.1,Mak A. F. T.1

Affiliation:

1. Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong

Abstract

A manual indentation protocol was established to assess the quasi-linear viscoelastic (QLV) properties of lower limb soft tissues. The QLV parameters were extracted using a curve-fitting procedure on the experimental indentation data. The load-indentation responses were obtained using an ultrasound indentation apparatus with a hand-held pen-sized probe. Limb soft tissues at four sites of eight normal young subjects were tested in three body postures. Four QLV model parameters were extracted from the experimental data. The initial modulus E0 ranged from 0.22 kPa to 58.4 kPa. The nonlinear factor E1 ranged from 21.7 kPa to 547 kPa. The time constant τ ranged from 0.05 s to 8.93 s. The time-dependent material parameter α ranged from 0.029 to 0.277. Large variations of the parameters were noted among subjects, sites, and postures.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference87 articles.

1. Bader D. L. , and BowkerP., 1983, “Mechanical characteristics of skin and underlying tissues in vivo,” Biomaterials, 4: 305–308.

2. Best T. M. , McElhaneyJ., GarrettW. E., and MyersB. S., 1994, “Characterization of the passive responses of live skeletal muscle using the quasi-linear theory of viscoelasticity,” J. Biomechanics, 27(4): 413–419.

3. Boone, D. A., and Harlan, J., 1992, “Considerations for computer interface design for prosthetics and orthotics: A user’s perspective,” Proc. 7th World Congress ISPO, Chicago, p. 157.

4. Boone D. A. , HarlanJ. S., and BurgessE. M., 1994, “Automated fabrication of mobility aids: Review of the AFMA process and VA/Seattle ShapeMaker software design,” J. Rehabil. Res. & Dev., 31(1): 42–49.

5. Brennan J. M. , and ChildressD. S., 1991, “Finite element and experimental investigation of above-knee amputee limb/prosthesis systems: A comparative study,” Advances in Bioengineering, ASME BED-20: 547–550.