Abstract

The Chandler loop is an artificial circulatory platform for in vitro hemodynamic experiments. In most experiments, the working fluid is subjected to a strain rate field via rotation of the Chandler loop, which, in turn, induces biochemical responses of the suspended cells. For low rotation rates, the strain rate field can be approximated using laminar flow in a straight tube. However, as the rotation rate increases, the effect of the tube curvature causes significant deviation from the laminar straight tube approximation. In this manuscript, we investigate the flow and associated strain rate field of an incompressible Newtonian fluid in a Chandler loop as a function of the governing nondimensional parameters. Analytical estimates of the strain rate from a perturbation solution for pressure driven steady flow in a curved tube suggest that the strain rate should increase with Dean number, which is proportional to the tangential velocity of the rotating tube, and the radius to radius of curvature ratio of the loop. Parametrically varying the rotation rate, tube geometry, and fill ratio of the loop show that strain rate can actually decrease with Dean number. We show that this is due to the nonlinear relationship between the tube rotation rate and height difference between the two menisci in the rotating tube, which provides the driving pressure gradient. An alternative Dean number is presented to naturally incorporate the fill ratio and collapse the numerical data. Using this modified Dean number, we propose an empirical formula for predicting the average fluid strain rate magnitude that is valid over a much wider parameter range than the more restrictive straight tube-based prediction.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3