Effect of Fiber Orientation and Strain Rate on the Nonlinear Uniaxial Tensile Material Properties of Tendon

Author:

Lynch Heather Anne1,Johannessen Wade1,Wu Jeffrey P.1,Jawa Andrew1,Elliott Dawn M.1

Affiliation:

1. McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA

Abstract

Tendons are exposed to complex loading scenarios that can only be quantified by mathematical models, requiring a full knowledge of tendon mechanical properties. This study measured the anisotropic, nonlinear, elastic material properties of tendon. Previous studies have primarily used constant strain-rate tensile tests to determine elastic modulus in the fiber direction. Data for Poisson’s ratio aligned with the fiber direction and all material properties transverse to the fiber direction are sparse. Additionally, it is not known whether quasi-static constant strain-rate tests represent equilibrium elastic tissue behavior. Incremental stress-relaxation and constant strain-rate tensile tests were performed on sheep flexor tendon samples aligned with the tendon fiber direction or transverse to the fiber direction to determine the anisotropic properties of toe-region modulus E0, linear-region modulus (E), and Poisson’s ratio (ν). Among the modulus values calculated, only fiber-aligned linear-region modulus E1 was found to be strain-rate dependent. The E1 calculated from the constant strain-rate tests were significantly greater than the value calculated from incremental stress-relaxation testing. Fiber-aligned toe-region modulus E10=10.5±4.7 MPa and linear-region modulus E1=34.0±15.5 MPa were consistently 2 orders of magnitude greater than transverse moduli (E20=0.055±0.044 MPa,E2=0.157±0.154 MPa). Poisson’s ratio values were not found to be rate-dependent in either the fiber-aligned (ν12=2.98±2.59, n=24) or transverse (ν21=0.488±0.653, n=22) directions, and average Poisson’s ratio values in the fiber-aligned direction were six times greater than in the transverse direction. The lack of strain-rate dependence of transverse properties demonstrates that slow constant strain-rate tests represent elastic properties in the transverse direction. However, the strain-rate dependence demonstrated by the fiber-aligned linear-region modulus suggests that incremental stress-relaxation tests are necessary to determine the equilibrium elastic properties of tendon, and may be more appropriate for determining the properties to be used in elastic mathematical models.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference32 articles.

1. Matyas, J. R., Anton, M. G., Shrive, N. G., and Frank, C. B., 1995, “Stress Governs Tissue Phenotype at the Femoral Insertion of the Rabbit Mcl,” J. Biomech., 28(2), pp. 147–157.

2. Woo, S. L.-Y., An, K.-N., Frank, C. B., Livesay, G. A., Ma, C. B., Zeminski, J., Wayne, J. S., and Myers, B. S., 2000, “Anatomy, Biology, and Biomechanics of Tendon and Ligament,” Orthopaedic Basic Science, J. A. Buckwalter, Einhorn, T. A., and Simon, S. R., eds., American Academy of Orthopaedic Surgeons, 2, pp. 581–616.

3. Quapp, K. M., and Weiss, J. A., 1998, “Material Characterization of Human Medial Collateral Ligament,” J. Biomech. Eng., 120(6), pp. 757–763.

4. Yamamoto, E., Hayashi, K., and Yamamoto, N., 2000, “Effects of Stress Shielding on the Transverse Mechanical Properties of Rabbit Patellar Tendons,” J. Biomech. Eng., 122(6), pp. 608–614.

5. Lynch, H. A., Johannessen, W., Bey, M. J., and Elliott, D. M., 2002, “Poisson’s Ratio and Modulus for Tendon Transverse and Longitudinal Fiber Orientations,” Transactions of the Orthopaedic Research Society, 26, p. 243243.