1. Central Technical Institute TNO, P.O. Box 342, Apeldoorn, The Netherlands
Abstract
Void fraction was measured with high-speed photography in a 26.7 m and a 40.1 m long, sodium-heated helically coiled steam generator tube of 0.018 m ID. The ratio of coil diameter to tube diameter was 38.9. The operating conditions for the tests were as follows: Pressure: 4–18 MN/m2, mass velocity: 429–1518 kg/m2s, heat flux: 0.013–0.42 MW/m2, outlet subcooling: 0.3–12.5 K, outlet steam quality: 0.000032–0.075. For vapor volumetric rate ratios greater than 0.4, the so-called distribution parameter is not affected by centrifugal forces, and is equal to 0.875. For vapor volumetric rate ratios smaller than 0.4, this parameter is affected by centrifugal forces and the aforesaid ratio. The incipient point of boiling and initial point of net vapor generation were determined with high-speed photography in the aforementioned 26.7 m long helical coil for the following range of operating conditions: Pressure: 4–18 MN/m2, mass velocity 757–1518 kg/m2s, heat flux: 0.082–0.413 MW/m2, outlet subcooling: 4.4–12.5 K. The data were correlated by using both the average and local values of the operating conditions.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
51 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Fluid Flow in Helically Coiled Pipes;Fluids;2023-11-27
2. Void fraction in helical coils during flow boiling with inlet subcooling;International Journal of Heat and Mass Transfer;2021-04
3. References;Two-Phase Flow, Boiling, and Condensation;2017-01-11
4. Unit Conversions;Two-Phase Flow, Boiling, and Condensation;2017-01-11
5. Physical Constants;Two-Phase Flow, Boiling, and Condensation;2017-01-11