Electro-Osmosis Modulated Viscoelastic Embryo Transport in Uterine Hydrodynamics: Mathematical Modeling

Author:

Narla V. K.1,Tripathi Dharmendra2,Anwar Bég O.3

Affiliation:

1. Department of Mathematics, GITAM (Deemed to be University), Hyderabad 502329, India e-mail:

2. Department of Sciences and Humanities, National Institute of Technology, Uttarakhand 246174, India e-mail:

3. Aeronautical and Mechanical Engineering, University of Salford, Manchester M54WT, UK e-mail:

Abstract

Embryological transport features a very interesting and complex application of peristaltic fluid dynamics. Electro-osmotic phenomena are also known to arise in embryo transfer location. The fluid dynamic environment in embryological systems is also known to be non-Newtonian and exhibits strong viscoelastic properties. Motivated by these applications, the present article develops a new mathematical model for simulating two-dimensional peristaltic transport of a viscoelastic fluid in a tapered channel under the influence of electro-osmosis induced by asymmetric zeta potentials at the channel walls. The robust Jeffrey viscoelastic model is utilized. The finite Debye layer electro-kinetic approximation is deployed. The moving boundary problem is transformed to a steady boundary problem in the wave frame. The current study carries significant physiological relevance to an ever-increasing desire to study intrauterine fluid flow motion in an artificial uterus. The consequences of this model may introduce a new mechanical factor for embryo transport to a successful implantation site. Hydrodynamic characteristics are shown to be markedly influenced by the electro-osmosis, the channel taper angle, and the phase shift between the channel walls. Furthermore, it is demonstrated that volumetric flow rates and axial flow are both enhanced when the electro-osmotic force aids the axial flow for specific values of zeta potential ratio. Strong trapping of the bolus (representative of the embryo) is identified in the vicinity of the channel central line when the electro-osmosis opposes axial flow. The magnitude of the trapped bolus is observed to be significantly reduced with increasing tapered channel length whereas embryo axial motility is assisted with aligned electro-osmotic force.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3