Affiliation:
1. Siemens Westinghouse Power Corporation, Pittsburgh, PA
Abstract
Reviewed are power system concepts employing the solid oxide fuel cell (SOFC) at atmospheric pressure in simple cycle; in an atmospheric pressure hybrid cycle with a gas turbine (SOFC/GT); and in a pressurized SOFC/GT hybrid (PSOFC/GT). Estimates of power system performance are presented and discussed. Simple atmospheric pressure SOFC systems designed for combined heat and power (CHP) application can approach 50% electric generation efficiency (net AC/LHV) and 80% fuel effectiveness [(net AC + useful heat)/LHV]. Pressurized SOFC systems with intercooled, recuperated, and SOFC-reheated GT cycles can approach 70% electric generation efficiency, while the atmospheric pressure SOFC/GT hybrid cycle and a simple pressurized SOFC/GT cycle can approach 55% and 60% generation efficiency, respectively. These high levels of efficiency are extraordinary in that they are achievable at the MW capacity level.
Publisher
American Society of Mechanical Engineers
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献