Design and Validation of a Novel Hand-Worn Sensor for Assessment of Dexterity in Neurological Conditions

Author:

Hayden Conor D.123,Murray Deirdre45,Geraghty Dermot6,Meldrum Dara7,Hardiman Orla45,Murphy Bruce P.128

Affiliation:

1. Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland

2. Department of Mechanical, Manufacturing and Biomedical Engineering, Trinity College Dublin , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland

3. Academic Unit of Neurology, Trinity Biomedical Sciences Institute, Trinity College Dublin , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland

4. Academic Unit of Neurology, Trinity Biomedical Sciences Institute, Trinity College Dublin , Dublin 2 D02 R590, Ireland ; , Dublin 9 D09 V2N0, Ireland

5. Neurocent Directorate Beaumont Hospital , Dublin 2 D02 R590, Ireland ; , Dublin 9 D09 V2N0, Ireland

6. Department of Mechanical, Manufacturing and Biomedical Engineering, Trinity College Dublin , Dublin 2 D02 R590, Ireland

7. Academic Unit of Neurology, Trinity Biomedical Sciences Institute, Trinity College Dublin , Dublin 2 D02 R590, Ireland

8. Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland ; , Dublin 2 D02 R590, Ireland

Abstract

Abstract Sensitive measurement of hand dexterity is important in many neurological conditions such as Stroke, Parkinson's Disease, or Amyotrophic Lateral Sclerosis (ALS). Current multi-item rating scales and performance-based tests lack sensitivity and contain subjective biases. This paper presents the design and validation of an objective, novel hand-worn dexterity measurement device that digitizes the finger tapping test (FTT), a widely used test in neurological practice. The device was designed to address predefined user needs and design requirements. It comprises two distinct sections, a mechanical system that attaches to a participant's thumb and index finger and an electronic system that captures/transmits data to a secure cloud storage. The accuracy (for four devices) was validated by plotting the known displacements against the calculated displacements, which returned slopes approximately equal to one. A maximum extension force of 0.51 N was required to extend the cord to 200 mm extension. Clinical testing was carried out on a small sample of healthy people (n = 3) and people with Amyotrophic Lateral Sclerosis (n = 3). Clean datasets were produced from participant's raw data graphs, from which new features describing a participant's FTT were extracted. The proposed dexterity device digitizes the FTT and provides clean, accurate, sensitive, and reliable data.

Funder

Health Research Board

Higher Education Authority

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference20 articles.

1. The ALSFRS-R: A Revised ALS Functional Rating Scale That Incorporates Assessments of Respiratory Function;J. Neurol. Sci.,1999

2. Movement Disorder Society-Sponsored Revision of the Unified Parkinson's Disease Rating Scale (MDS-UPDRS): Process, Format, and Clinimetric Testing Plan;Mov. Disord.,2007

3. The Disabilities of the Arm, Shoulder and Hand (DASH) Outcome Questionnaire: Longitudinal Construct Validity and Measuring Self-Rated Health Change After Surgery;BMC Musculoskeletal Disord.,2003

4. Adult Norms for a Commercially Available Nine Hole Peg Test for Finger Dexterity;Am. J. Occup. Ther.,2003

5. An Objective and Standardized Test of Hand Function;Arch. Phys. Med. Rehabil.,1969

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3