Comparison of Balloon-Expandable Valve and Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A Patient-Specific Numerical Study

Author:

Li Jianming1,Yan Wentao1,Wang Wenshuo2,Wang Shengzhang3,Wei Lai2

Affiliation:

1. Department of Aeronautics and Astronautics, Fudan University, Shanghai 200433, China; Institute of Biomechanics, Fudan University, Shanghai 200433, China

2. Department of Cardiac Surgery, Zhongshan Hospital Affiliated to Fudan University, Shanghai 200032, China

3. Department of Aeronautics and Astronautics, Fudan University, Shanghai 200433, China; Academy for Engineering and Technology, Institute of Biomedical Engineering Technology, Fudan University, Shanghai 200433, China; Institute of Biomechanics, Fudan University, Shanghai 200433, China

Abstract

Abstract Transcatheter aortic valve replacement (TAVR) is a minimally invasive strategy for the treatment of aortic stenosis. The complex postoperative complications of TAVR were related to the type of implanted prosthetic valve, and the deep mechanism of this relationship may guide the clinical pre-operative planning. This technical brief developed a numerical method of TAVR to compare the outcome difference between balloon-expandable valve and self-expandable valve and predict the postoperative results. A complete patient-specific aortic model was reconstructed. Two prosthetic valves (balloon-expandable valve and self-expandable valve) were introduced to simulate the implantation procedure, and postprocedural function was studied with fluid–structure interaction method, respectively. Results showed similar stress distribution for two valves, but higher peak stress for balloon-expandable valve model. The balloon-expandable valve was associated with a better circular cross section and smaller paravalvular gaps area. Hemodynamic parameters like cardiac output, mean transvalvular pressure difference, and effective orifice area (EOA) of the balloon-expandable valve model were better than those of the self-expandable valve model. Significant outcome difference was found for two prosthetic valves. Balloon-expandable valve may effectively decrease the risk and degree of postoperative paravalvular leak, while self-expandable valve was conducive to lower stroke risk due to lower aortic stress. The numerical TAVR simulation process may become an assistant tool for prosthesis selection in pre-operative planning and postoperative prediction.

Funder

National Natural Science Foundation of China

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference30 articles.

1. Calcification in Aortic Stenosis: The Skeleton Key;J. Am. Coll. Cardiol.,2015

2. Bicuspid Aortic Valve Disease;J. Am. Coll. Cardiol.,2010

3. Current Status of Transcatheter Aortic Valve Replacement;J. Am. Coll. Cardiol.,2012

4. Prospective Comparison Between Three TAVR Devices: ACURATE Neo Vs. CoreValve Vs. Sapien XT. A Single Heart Team Experience in Patients With Severe Aortic Stenosis;Catheter Cardiovasc. Interventions,2017

5. Network Meta-Analysis on the Comparative Effectiveness and Safety of Transcatheter Aortic Valve Implantation With CoreValve or Sapien Devices Versus Surgical Replacement;Heart Lung Vessels,2014

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3