Influence of scan time point and volume of intravenous contrast administration on blood-pool and liver SUVmax and SUVmean in [18F] FDG PET/CT

Author:

Braun Timm,Manava Panagiota,Ludwigs Sigrid,Lell Michael,Schoen Matthias

Abstract

Summary Aim: To investigate the influence of scan time point and volume of intravenous contrast material in 18F-FDG PET/CT on maximum and mean standardized uptake values (SUVmax/mean) in bloodpool and liver. Methods: In 120 patients scheduled for routine whole-body 18F-FDG PET/CT the maximum and mean standardized uptake values (SUVmax/SUVmean) in the liver and blood pool were measured after varying scan time-point (delay 0 s-140 s post injectionem) and volume of contrast material (CM; 0 ml, 80 ml, 100 ml of 300 mg/ml of Iodine). Six groups of 20 patients were investigated: (1) without intravenous CM, (2-5) injection of 100 ml CM with a delay of 80 s (2), 100 s (3), 120 s (4), 140 s (5), and 80 ml CM and a delay of 100 s (6). SUVmax, SUVmean, maximum Hounsfield units (HUmax) and average Hounsfield units (HUav) were calculated with the use of manually drawn regions of interests (ROIs) over the aortic arch and healthy liver tissue. Results: SUVmax in bloodpool was significantly higher in group 3, 4 and 6 compared to group 1. Groups 2 and 5 also showed higher mean values of SUVmax, but the difference was not significant. SUVmean in bloodpool was also higher in groups 2, 3, 4, 5 and 6 compared to group 1, but the differences were only statistically significant in group 3. Both SUVmax and SUVmean in healthy liver tissue did not show significant differences when compared to the non contrast-enhanced control group. Conclusion: SUVmax and to a lesser extent SUVmean measured in CM enhanced FDG PET/CT in blood pool could be significantly altered in high contrast CT examinations. This should be kept in mind in PET/CT protocols and evaluation relying on SUVmax and SUVmean, for example when used in the assessment of therapy response, especially in highly vascularized tumor lesions.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3