Six-month evaluation of novel bioabsorbable scaffolds composed of poly-L-lactic acid and amorphous calcium phosphate nanoparticles in porcine coronary arteries

Author:

Dinh Nguyen Thanh1,Feng Gaoke1ORCID,Yi Xin1,Lyu Yongnan1,Lan Zhiyuan234,Xia Jinggang5,Wu Tim234,Jiang Xuejun1

Affiliation:

1. Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China

2. VasoTech Inc., Lowell, MA, USA

3. Department of Plastic Engineering, University of Massachusetts Lowell, Lowell, MA, USA

4. Department of Cardiology, Xuanwu Hospital, Capital Medical University, Beijing, China

5. Dongguan TT Medical, Inc., Dongguan, China

Abstract

Objective Using coronary angiography and intravascular ultrasound methods to evaluate the performance of the novel fully bioabsorbable scaffold (NFBS) composed of poly-L-lactic acid/amorphous calcium phosphate (PLLA/ACP) at six-month follow-up by comparing with PLLA scaffolds Methods Twelve PLLA/ACP scaffolds and 12 PLLA scaffolds were implanted into the coronary arteries of 12 miniature pigs. Quantitative coronary angiography (QCA) was used to measure the reference vessel diameter (RVD), mean lumen diameter (MLD) and late lumen loss (LLL). According to IVUS images, we calculated the strut malapposition rate (SMR) at post implantation, strut overlap rate (SOR), reference vessel area (RVA), mean stent area (MSA), mean lumen area (MLA) and luminal patency rate (LPR) at six-month follow-up. The radial strength of the scaffold was evaluated using a catheter tensile testing machine. Results QCA results indicated that, at six month, MLD of PLLA/ACP scaffolds was greater than those of PLLA scaffolds (2.47 ± 0.22 mm vs. 2.08 ± 0.25 mm, P < 0.05); LLL of PLLA/ACP scaffolds was less than those of PLLA scaffolds (0.42 ± 0.20 mm vs. 0.75 ± 0.22 mm, P < 0.05). IVUS results showed the SMR and SOR were all significantly less with the PLLA/ACP scaffolds than the PLLA scaffolds (5.84% ± 3.56% vs. 17.72% ± 4.86%, P < 0.05) (6.17% ± 4.63% vs. 17.65% ± 4.29%, P < 0.05). MSA, MLA and LPR of the PLLA/ACP scaffolds were all greater than those of PLLA scaffolds (6.35 ± 0.45 mm2 vs. 5.35 ± 0.51 mm2, P < 0.05) (4.76 ± 0.46 mm2 vs. 3.77 ± 0.46 mm2, P < 0.05) (78.01% ± 12.29% vs. 61.69% ± 9.76%, P < 0.05). Radial strength of PLLA/ACP scaffold at six month was greater than that of PLLA scaffold (76.33 ± 3.14 N vs. 67.67 ± 3.63 N). Conclusion The NFBS had less stent recoil, better lumen patency rate and greater radial strength than PLLA scaffolds. The results suggest the NFBS scaffolds can maintain the structural strength and functional performance, which are effective for up to six months when implanted in porcine coronary arteries.

Funder

the NSFC Guidance fund project of the Renmin Hospital of Wuhan University

the Guandong Innovative and Entrepreneurial Research Team Program

the Fundamental Research Funds for the Central Universities of China

the Wuhan Youth Science and Technology Chenguang Plan

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3