Determination of Crystallinity and Crystal Structure of Hylamer™ Polyethylene after in vivo Wear

Author:

Visentin M.1,Stea S.2,De Clerico M.2,Reggiani M.3,Fagnano C.3,Squarzoni S.4,Toni A.5

Affiliation:

1. Laboratorio di Tecnologia Medica Istituti Ortopedici Rizzoli, Bologna 40136, Italy,

2. Laboratorio di Tecnologia Medica Istituti Ortopedici Rizzoli, Bologna 40136, Italy

3. Dipartimento di Biochimica G. Moruzzi Sez di Chimica e Propedeutica Biochimica Bologna 40126, Italy

4. ITOI - CNR, Unita’ di Bologna c/o Istituti Ortopedici Rizzoli Bologna 40136, Italy

5. I Divisione di Ortopedia e Traumatologia Istituti Ortopedici Rizzoli, Bologna 40136, Italy

Abstract

Hylamer™ polyethylene is a crystalline form of polyethylene of 70% crystallinity whereas conventional polyethylene (PE) has 50% crystallinity. Crystallinity is the percentage by weight of the crystalline phase present in the whole polymer, which comprises both amorphous and crystalline phases.Clinical experience has shown that Hylamer™ components used in joint prostheses, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which leads to osteolysis. The authors have analyzed the crystallinity of polyethylene liners removed from seven patients who had received Hylamer™ polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening, using Raman spectroscopy coupled with partial least squares (PLS) analysis. The results have been compared to those of two controls who had received Hylamer™ polyethylene implants sterilized by gamma irradiation in a nitrogen atmosphere. The crystal structure of wear particles released into the tissues from the Hylamer™ liners sterilized by gamma rays in air is also studied. The materials undergoing two different types of sterilization methods show different crystallinity values (71.50 vs. 69.43), but the crystallinity do not change according to wear (worn and unworn liner region). Both monoclinic and orthorhombic phases are present in the liner, while in wear debris prevalently monoclinic crystals are found in both types of sterilized liners. Different crystallinity rates can explain different wear rates observed in vivo.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3