Osteoconductivity of bioactive Ti-6Al-4V implants with lattice-shaped interconnected large pores fabricated by electron beam melting

Author:

Goto Mikinobu1ORCID,Matsumine Akihiko2,Yamaguchi Seiji3,Takahashi Hiroyuki4,Akeda Koji1,Nakamura Tomoki1,Asanuma Kunihiro1,Matsushita Tomiharu3,Kokubo Tadashi3,Sudo Akihiro1

Affiliation:

1. Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Japan

2. Department of Orthopedics and Rehabilitation Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan

3. Department of Biomedical Sciences, Graduate School of Life and Health Sciences, Chubu University College of Life and Health Sciences, Aichi Japan

4. Teijin Nakashima Medical Co., Ltd, Okayama, Japan

Abstract

Additive manufacturing has facilitated the fabrication of orthopedic metal implants with interconnected pores. Recent reports have indicated that a pore size of 600 μm is beneficial for material-induced osteogenesis. However, the complete removal of the metal powder from such small pores of implants is extremely difficult especially in electron beam melting (EBM). We therefore developed a new type of Ti-6Al-4V implant with lattice-shaped interconnected pores measuring 880–1400 μm, which allowed for the easy removal of metal powder. This implant was fabricated by EBM and treated with NaOH, CaCl2, heat, and water (ACaHW treatment) to render the metal surface bioactivity. In the present study, the mechanical and chemical property of the implants and the biocompatibility were evaluated. The SEM and micro-CT images demonstrated the 3D interconnectivity of the porous structures. The average porosity of the porous titanium implant was 57.5%. The implant showed maximum compressive load of 78.9 MPa and Young's modulus of 3.57 GPa which matches that of human cortical bone. ACaHW treatment of the porous Ti-6Al-4V implants induced apatite formation in simulated body fluid in vitro. The ACaHW-treated porous implants harvested from rabbit femoral bone showed direct bonding of bone to the metal surface without interposition of fibrous tissue. The porous ACaHW-treated implant had a higher affinity to the bone than the untreated one. The mechanical strength of implant fixation assessed using the push-out test was significantly higher in the ACaHW-treated implant than in untreated one. FE-SEM analysis and EDX mapping after push-out test of solid implants showed a lot of bone tissue patches on the surface of the ACaHW-treated implant. These results suggest that the new ACaHW-treated Ti-6Al-4V implant with lattice-shaped interconnected pores is a superior alternative to conventional materials for medical application.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3