Selectivity Quantification with the Fluorescent Quantitative Model-Assisted Semi-Selective Probe (Carbon Dots): Accurate Determination of Chlortetracycline in Aqueous Environments with Interference

Author:

Chen Yang12,Yan Xiu-Fang23,Bin Jun23,Liang Yan-Mei1,Wang Fu-Xin1,Yang Min1,Kang Chao1ORCID

Affiliation:

1. School of Chemistry and Chemical Engineering, Guizhou University, Guiyang, China

2. Key Laboratory of Tobacco Quality Research of Guizhou Province, Guizhou University, Guiyang, China

3. College of Tobacco Science, Guizhou University, Guiyang, China

Abstract

Probes such as carbon dots (C-dots) have extensive and important applications in the quantitative analysis of complex biological and environmental systems. However, the development of probes is often hindered by incomplete selectivity, i.e., a probe that responds to one substance is also prone to respond to coexisting structurally similar substances. Therefore, the above dilemma often leads to be developed as semi-selective probes, so that the development of probes is abandoned halfway. This work shows how a semi-selective probe can enhance selectivity by combining a proper multivariate calibration model. Primarily, we developed a semi-selective fluorescent probe that responded to tetracyclines (TCs) with discarded tobacco leaves. Then, we introduced the multivariate quantitative fluorescence model (QFM) to enhance its selectivity and solve the problem of fluorescence spectral shift. For the determination of chlortetracycline (CTC) with this semi-selective C-dots probe in mineral and lake water samples and compared to the traditional quantitative model, the introduced QFM resulted in an average relative predictive error (ARPE) in mineral water spiked samples decreased from 57.1 to 5.6%, which reduced the ARPE in the lake water spiked samples from 18.1 to 4.7%. The above results show that the QFM-assisted semi-selective probe C-dots strategy (QFMC−dots) can enhance selectivity, and QFMC−dots achieved high-selective and accurate determination of CTC in interfering mineral and lake water samples, with the limit of detection and limit of quantitation of 0.55 and 1.66 μM, respectively. The proposed strategy of enhancing selectivity by introducing a proper multivariate calibration model can reduce the difficulty and increase success rate of developing probes, which can be expected to provide an interesting alternative for the development of probes, especially when encountering semi-selective problems.

Funder

Science and Technology Project of China National Tobacco Corporation Bijie Company

Guizhou Provincial Science and Technology Projects

National Key R&D Program of China

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献