Analytical Evaluation of Particle-Enhanced Immunonephelometric Assays for C-Reactive Protein, Serum Amyloid a and Mannose-Binding Protein in Human Serum

Author:

Ledue Thomas B1,Weiner Debra L2,Sipe Jean D3,Poulin Sue E1,Collins Marilyn F1,Rifai Nader2

Affiliation:

1. Foundation for Blood Research, 69 US Route 1, PO Box 190, Scarborough, Maine, ME 04070-0190

2. Children's Hospital and Harvard Medical School, Boston, Massachusetts

3. Boston University School of Medicine, Boston, Massachusetts, USA

Abstract

Against a background of growing interest in more sensitive assays for quantifying various acute phase proteins, we evaluated the performance of recently developed tests for C-reactive protein (CRP), serum amyloid A (SAA) and mannose-binding protein (MBP) on the Behring nephelometer II (BN II). Sample results outside the calibration ranges of 3·5 to 220 mg/L for CRP, 3·3 to 215 mg/L for SAA and 0·09 to 5·6 mg/L for MBP were automatically re-measured at another dilution. The lower limits of detection were 0·01, 0·7 and 0·01 mg/L for CRP, SAA and MBP, respectively. The coefficients of variation (CV) for intra- ( n ⩾ 20) and inter- ( n ⩾ 15) assay precision were < 5·2% and < 8·5%, respectively, for the three proteins at concentrations representing low, normal and high. Linearity for each method was within 5% of the expected values throughout the calibration range. We observed no significant interference from bilirubin (up to 300 mg/L) or haemoglobin (up to 10 g/L) for the three tests. Method comparison studies performed for CRP and SAA yielded the following results: y (CRP on BN II) = 0·75 x (ELISA, Hemagen) −0·25 mg/L ( r = 0·981, Sy/x = 2·1 mg/L; y (SAA on BN II) = 1·44 x (ELISA, Hemagen) −9·9 mg/L ( r = 0·972, Sy/x = 6·9 mg/L), where ELISA is enzyme-linked immunosorbent assay. Reference intervals established in 261 adult blood donors (aged 36·2 ± 9·0 years) were found to be log-normal with 2·5th, 50th and 97·5th centiles of < 0·17, 100 and 10·1 mg/L for CRP, < 0·84, 2·10 and 9·70 mg/L for SAA; and 0·30, 1·28 and 4·10 mg/L for MBP. We observed no relationship with CRP concentration and age; however, SAA levels increased with age while MBP levels decreased. The BN II provides a simple, rapid and sensitive system for measuring CRP, SAA and MBP in human serum.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 276 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3