Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion

Author:

da Silva Camassuti Patrícia Aparecida1,Marcolino Alexandre'Marcio23,Tamanini Guilherme2,Barbosa Rafael Inácio24,Barbosa Amanda Matias1,de Cássia Registro Fonseca Marisa12

Affiliation:

1. Physiotherapy Course, University of São Paulo, Ribeirão Preto, Brazil

2. Post-graduate Program in Rehabilitation and Functional Performance, University of São Paulo, Ribeirão Preto, Brazil

3. Physiotherapy Course, Paulista University, Ribeirão Preto, Brazil

4. Physiotherapy Course, Federal University of Santa Catarina, Araranguá, Brazil

Abstract

Introduction Assessment of the wrist is essential in hand rehabilitation. The flexible electrogoniometer has been used to measure joint range of motion in the wrist, although it has lack of reliability. The objectives of the study were to examine intra- and inter-examiner reliability, as well as inter-device reliability, of wrist range of motion obtained by a flexible electrogoniometer. Methods Twenty-four right-handed individuals (12 men and 12 women) took part in the study. Participants were actively and randomly subjected to radial and ulnar deviation, flexion and extension of the right wrist. The motions were measured by both the universal goniometer (CARCI®) and the electrogoniometer (MIOTEC®). Two examiners carried out three series of measurements. One of the examiners performed repeated measurement after seven days. The Intraclass Correlation Coefficient, standard error of measurement and the Bland-Altman limits of agreement were used for data analysis. Results Data showed excellent intra- and inter-examiner reliability for all movements with the electrogoniometer (Intraclass Correlation Coefficient > 0.90), except for the inter-examiner analysis of wrist flexion, with an Intraclass Correlation Coefficient of 0.89. The correlation between the devices was deemed to be satisfactory. Even though the excellent reliability and low standard error of measurement results were presented, Bland-Altman graphs showed some discrepant data. Conclusion Based on this sample, we suggest that this electrogoniometer is a reliable device regarding intra- and inter-examiner for clinical application when compared with a universal goniometry for wrist motion.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3