A comparative study on the value of lower airway exhaled nitric oxide combined with small airway parameters for diagnosing cough-variant asthma

Author:

Bai Haodong1,Shi Cuiqin1,Yu Sue1,Wen Siwan1,Sha Bingxian1,Xu Xianghuai2ORCID,Yu Li23ORCID

Affiliation:

1. Department of Pulmonary and Critical Care Medicine, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China

2. Department of Pulmonary and Critical Care Medicine, Tongji Hospital, School of Medicine, Tongji University, 389 Xincun Road, Shanghai 200065, China

3. Department of Allergy, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China

Abstract

Background: The diagnosis of cough-variant asthma (CVA) is based on bronchial provocation test, which is challenging to be conducted. Most CVA patients have type 2 airway inflammation and small airway dysfunction. FeNO200, reflecting small airway inflammation, may be used to diagnose CVA. Objective: This study aimed to explore and compare the value of lower airway exhaled nitric oxide (FeNO50, FeNO200, and CaNO) combined with small airway parameters for diagnosing CVA. Methods: Chronic cough patients who attended the clinic from September 2021 to August 2022 were enrolled and divided into CVA group ( n = 71) and non-CVA (NCVA) group ( n = 212). The diagnostic values of FeNO50, FeNO200, concentration of alveolar nitric oxide (CaNO), maximal mid-expiratory flow (MMEF), forced expiratory flow at 75% of forced vital capacity (FEF75%) and forced expiratory flow at 50% of forced vital capacity (FEF50%) for CVA were evaluated. Results: FeNO50 [39(39) ppb versus 17(12) parts per billion (ppb), p < 0.01], FeNO200 [17(14) ppb versus 8(5) ppb, p < 0.01] and CaNO [5.0(6.1) ppb versus 3.5(3.6) ppb, p < 0.01] in CVA group were significantly higher than those in NCVA group. The optimal cut-off values of FeNO50, FeNO200, and CaNO for diagnosis of CVA were 27.00 ppb [area under the curve (AUC) 0.88, sensitivity 78.87%, specificity 79.25%], 11.00 ppb (AUC 0.92, sensitivity 88.73%, specificity 81.60%) and 3.60 ppb (AUC 0.66, sensitivity 73.24%, specificity 52.36%), respectively. For diagnosing CVA, the value of FeNO200 was better than FeNO50 ( p = 0.04). The optimal cut-off values of MMEF, FEF75%, and FEF50% for the diagnosis of CVA were 63.80% (AUC 0.75, sensitivity 53.52%, specificity 86.32%), 77.9% (AUC 0.74, sensitivity 57.75%, specificity 83.49%) and 73.50% (AUC 0.75, sensitivity 60.56%, specificity 80.19%), respectively. The AUCs of FeNO50 combined with MMEF, FEF75%, and FEF50% for the diagnosis of CVA were all 0.89. The AUCs of FeNO200 combined with MMEF, FEF75%, and FEF50% for the diagnosis of CVA were all 0.93. Conclusion: FeNO200 > 11 ppb contributed strongly for differentiating CVA from chronic cough, especially in patients with small airway dysfunction.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Pharmacology (medical),Pulmonary and Respiratory Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3