Tomographic 3D ultrasound for grading stenosis of superficial femoral artery

Author:

Alzahrani Adel12,Sultan Salahaden R3ORCID,Aslam Mohammed2

Affiliation:

1. Diagnostic Radiology, King Abdullah Medical City, Makkah, Saudi Arabia

2. Vascular Laboratory, Hammersmith Hospital, Imperial College NHS Healthcare Trust, London, UK

3. Radiologic Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia

Abstract

Introduction Treatment decision of lower extremity peripheral arterial disease (PAD) is governed by the severity of stenosis. Tomographic 3D ultrasound (t3DUS) is a reliable imaging technique for measuring vessel stenosis. In this study we attempted to provide a precise measurement of superficial femoral artery (SFA) stenosis using t3DUS in patients with PAD. Methods t3DUS was used to measure maximum stenosis percentage in SFA from 50 patients with lower extremity PAD. The maximum stenosed segment in SFA was defined using Duplex 2DUS aliasing was noted. The peak systolic velocity (PSV) was measured at the maximum stenotic site and proximal to aliasing for calculating the velocity ratio. The association between blood flow velocity ratio and the degree of stenosis measured using Duplex 2DUS and t3DUS, respectively, was assessed using Spearman rank correlation. Results There was a strong positive correlation between velocity ratio and degree of stenosis in SFA measured using t3DUS (correlation value (r) = 0.99, p < 0.001). The correlation between Stenosis percentage and velocity ratio in SFA are as followed: <50:<2; 50–54:2–2.4; 55–59:2.5–2.9; 60–64:3–3.4; 65–69:3.5–3.9; 70–74:4–4.4; 75–79:4.5–4.9; >80:>5. t3DUS can be used to provide precise measurement of the severity of SFA stenosis in patients with lower extremities arterial disease. The established criteria for grading SFA stenosis in this study can be applied to the current practice alongside Duplex 2DUS as it showed a strong positive correlation with velocity ratio. Further studies investigating the sensitivity and specificity of t3DUS in the assessment of stenosis in lower limbs arteries are required.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3