Abstract

Three different simulation tools were used to simulate a low energy terraced house in the south of Sweden. The software tools all use dynamic models to calculate, for example, the energy demand for heating and the indoor temperatures. The aim of this paper is to discuss the relative importance to the annual energy demand of different energy aspects of a Swedish low-energy house. Both measured and simulated values are considered and compared. The focus is on the impact of choice of software, the habits of the tenants, and the relative impact of different design parameters such as ventilation rates. The measured values for total electricity demand range from about 6000 kWh to over 12 000 kWh, the average demand being 8020 kWh. The annual predicted total energy demand using three different simulation software tools deviated by about 2%. The energy use deviation due to airflow control was about 10%, and the deviation due to differences in heat exchanger efficiency was about 20% and the deviation in annual energy use due to differences in internal gains due to differences in tenant habits, assumed in the models, was 7%. Furthermore, when comparing the predicted energy use during the design process of the low-energy building with actual measurements after the tenants have moved in, these differ about 50% in average for this specific case. Practical application: Building energy simulation software is often used to make predictions of how different construction materials, design principles and operation influence the energy balance and indoor thermal comfort. It is therefore important that the output of these software tools is trustworthy and accurate. This paper discusses the importance of accurate input data during the design process in order to achieve a valid prediction of energy use with emphasis on tenants' behaviour. It was shown that the deviations in a parametric study were larger than the deviations in the comparison between the results from the three simulation tools. This indicates a need for more accurate models for modelling tenant behaviour and habits rather than more accurate building component models.

Publisher

SAGE Publications

Subject

Building and Construction

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3