Supradiaphragmatic central venous catheter malposition detection using the parasternal long-axis echocardiographic view and dextrose 50% contrast solution: A pilot study

Author:

Che Rahim Mohd Jazman1ORCID,Abdull Wahab Shaik Farid1,Fauzi Mohd Hashairi1,Nadarajan Chandran1,Ab Hamid Siti Azrin1

Affiliation:

1. School of Medical Sciences, Universiti Sains Malaysia – Kampus Kesihatan, Kelantan, Malaysia

Abstract

Background Contrast-enhanced ultrasonography (CEUS) using saline was studied to detect supradiaphragmatic central venous catheter malposition. Commonly used echocardiographic views are apical 4-chamber (A4c) and subcostal views. However, this standard method is not feasible in certain situations. We explored the feasibility of the right ventricle inflow parasternal long axis (RVI-PLAX) echocardiographic view and dextrose 50% (D50%) contrast solution for detecting supradiaphragmatic central venous catheter malposition. Method This pilot study screened 60 patients who underwent ultrasound-guided supradiaphragmatic central venous catheter insertion. We compared the investigators' guidewire's J-tip detection, D50% rapid atrial swirl sign (RASS) findings on the RVI-PLAX view and the central venous catheter tip on chest radiograph. We also compared the mean capillary blood sugar level before and after the 5 ml D50% flush. Results No guidewire J-tips were detected from the RVI-PLAX view. The first and second investigators’ diagnosis of central venous catheter malposition detected on RVI-PLAX CEUS achieved an almost perfect agreement (κ = 1.0 (95% confidence interval (CI): 0.90 to 1.0), p < .0001). The RVI-PLAX CEUS was not able to detect two central venous catheter malpositions (one atrial malposition and one left brachiocephalic vein venous catheter malposition). The capillary blood sugar was significantly elevated (8.96 mmol/L vs. 9.75 mmol/L) after D50% flush ( p < 0.005) with no complications reported within 30 minutes after the D50% flush. Conclusion RVI-PLAX view should not be used for guidewire detection. CEUS using D50% and RVI-PLAX view are potentially useful tools in detecting central venous catheter malposition. Further studies comparing them with conventional methods are needed.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3