Abstract

Objectives This study compared the effectiveness of a new supraglottic airway device (SGAD) in cats undergoing anaesthesia using two types of mechanical ventilation: volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV). Methods A total of 13 healthy cats (five male, eight female; median age 2 years [range 1–3]) were randomly allocated to either VCV or PCV. Five tidal volumes (6, 8, 10, 12 and 14 ml/kg) and five peak inspiratory pressures (4, 5, 6, 7 and 8 cmH2O) were randomly applied with a minute ventilation of 100 ml/kg/min. Various parameters, such as blood pressure, gas leakage, end-tidal CO2 (ETCO2) and work of breathing (WOB), were measured while using VCV or PCV. Results The occurrence of hypotension (mean arterial blood pressure <60 mmHg) was slightly less frequent with VCV (38 events, 65 ventilating sessions) than with PCV (40 events, 65 ventilating sessions), but this difference did not reach statistical significance ( P = 0.429). The number of leakages did not differ between the VCV group (3 events, 65 ventilating sessions) and the PCV group (3 events, 65 ventilating sessions) ( P = 1.000). Hypercapnia was identified when using VCV (10 events, 65 ventilating sessions) less frequently than when using PCV (17 events, 65 ventilating sessions), but this difference did not reach statistical significance ( P = 0.194). The study found a significantly higher WOB in the PCV group compared with the VCV group ( P <0.034). Conclusions and relevance The present results suggested that both VCV and PCV can be used with an SGAD during anaesthesia, with VCV preferred for prolonged mechanical ventilation due to its lower workload. Adjusting tidal volume or inspiratory pressure corrects hypercapnia.

Funder

faculty of veterinary medicine, kasetsart university

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3