Long-term ophthalmic anatomical and functional outcomes after surgical removal of intraorbital foreign bodies

Author:

Grewal Aditi Mehta1ORCID,Singh Manpreet1ORCID,Yadav Deepti1,Kaur Manpreet1,Singh Jyoti1,Sharma Manjula1,Zadeng Zoramthara1,Gupta Pankaj1

Affiliation:

1. Department of Ophthalmology, Advanced Eye Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India

Abstract

Purpose: To analyze the anatomical and functional ophthalmic parameters after the surgical removal of various intraorbital foreign bodies. Methods: A retrospective analysis of medical records was performed featuring detailed history, ophthalmic examination, orbital computed tomographic scans, treatment details, and outcomes. The analyzed anatomical factors included extraocular movements, the position of the eyeball (proptosis, dystopia, and enophthalmos), and fullness of orbital sulci. The functional assessment was based on visual acuity, pupillary reactions, and diplopia. The outcomes were defined as complete, partial, and failure after a minimum follow-up of 1 year. Results: Of 32 patients, the organic and inorganic intraorbital foreign bodies were surgically removed from 18 (56.25%) and 14 (43.75%) orbits, respectively. At presentation, anatomically the extraocular movement restriction, proptosis/dystopia/enophthalmos, and orbital sulcus fullness were noted in 26 (81.25%), 24 (75%), and 15 (46.88%), respectively. Functionally, diminished visual acuity, diplopia, and pupil abnormalities were seen in 27 (84.38%), 14 (43.75%), and 8 (25%), respectively. After intraorbital foreign body removal at a mean follow-up of 14 months, the improvement of anatomical factors (same sequence) were observed in 8 (30.77%), 20 (83.33%), and 12 (80%), respectively. In functional factors (same sequence), the improvement was noted in none (0%), 13 (92.86%), and 5 (62.5%), respectively. Hence, the majority of patients (n = 20, 62.5%) achieved partial success, while 8 (25%) had complete success. Four (12.5%) had treatment failure despite similar management protocols. Conclusion: The anatomical outcomes are better than the functional outcomes after surgical removal of the intraorbital foreign bodies. The visual acuity does not improve considerably after the surgical removal of intraorbital foreign bodies. Overall, the wooden intraorbital foreign bodies have poorer anatomical and functional prognosis.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3