Comparison of using Galilei Dual Scheimpflug Analyzer G4 and Barrett formula in predicting low cylinder preoperatively for cataract surgeries

Author:

Ho Yi-Ju1,Sun Chi-Chin23,Lee Jiahn-Shing1,Lin Ken-Kuo1,Hou Chiun-Ho14

Affiliation:

1. Department of Ophthalmology, Linkou Chang Gung Memorial Hospital, Taoyuan City

2. Department of Ophthalmology, Keelung Chang Gung Memorial Hospital, Keelung City

3. Department of Chinese Medicine, College of Medicine, Chang Gung University, Taoyuan City

4. College of Medicine, Chang Gung University, Taoyuan City

Abstract

Purpose: To compare corneal astigmatism estimation from Barrett toric calculator, with measurement from Galilei Dual Scheimpflug Analyzer G4 in low corneal cylinder patients. Methods: Preoperative corneal astigmatism was measured using Auto Kerato-Refractometer (AutoKM), IOL Master, and Galilei G4 (combined Placido-dual Scheimpflug analyzer) and was processed by Barrett toric calculator with measurements obtained from Auto Kerato-Refractometer and from IOL Master. A total of 42 eyes undergoing cataract surgery with nontoric intraocular lens implantation were included. Corneal astigmatism was calculated based on manifest refractive astigmatism with implications of surgically induced astigmatism. Errors in predicted residual astigmatism were calculated by the difference between postoperative manifest cylindrical refractive error and preoperative corneal cylinder using vector analysis. Results: Centroid error in predicted residual astigmatism was with-the-rule 0.36 D for AutoKM and 0.48 D for IOL Master, was lower at 0.24 D for the Barrett–IOL Master, and was lowest at 0.21 D for the Barrett–AutoKM ( p < .001). The Galilei G4 demonstrated the highest centroid error for SimK (0.53 D) and lower for total corneal power (0.49 D). The Barrett toric calculator obtained the lowest median absolute error in predicted residual astigmatism for AutoKM (0.43 D) and IOL Master (0.54 D). The Barrett–IOL Master demonstrated that 61% and 76% of eyes were within 0.50 and 0.75 D of the predicted residual astigmatism, respectively. Conclusion: The Barrett–IOL Master had more accurate prediction of residual astigmatism for low astigmatism eyes before cataract surgery compared to Galilei Dual Scheimpflug Analyzer G4 in this study.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3