Applying a dual-Scheimpflug camera to measure tear film thickness

Author:

Keren Shay12,Mimouni Michael3ORCID,McCallum Ewan2,Rabina Gilad1ORCID,Levinger Eliya1

Affiliation:

1. Ophthalmology Department, Tel-Aviv Medical Center, Affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel

2. Oxford Eye Hospital, John Radcliffe Hospital, Oxford, UK

3. Department of Ophthalmology, Rambam Health Care Campus and the Bruce and Ruth Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel

Abstract

Purpose: To assess the tear film thickness in healthy individuals by using a dual-Scheimpflug camera and topical 0.1% fluorescein. Methods: A prospective study on healthy individuals who underwent a bilateral tomography examination using the GALILEI dual-Scheimpflug with assessments of the thinnest and central corneal thickness (TCT and CCT, respectively), at baseline and 1 min after applying 2 and 4 µl of 0.1% fluorescein (30 min apart) under topical anesthesia with Oxybuprocaine 0.4%. Inclusion criteria were lack of dry eye disease symptoms and exclusion criteria were contact lens usage, eye drops usage, previous refractive surgery or any ocular surgery. All individuals scored zero on the ocular surface disease index (OSDI) questionnaire. Results: A total of 62 eyes of 31 participants were included in this study. The mean age was 35.3 ± 10.88 (range 18–62). The mean TCT in was 549.16 µm in the right eye (RE) and 547.84 µm in the left eye (LE). After instillation of 2 µl of 0.1% fluorescein mean TCT increase by 27.84 µm in the RE and by 26.35 µm in the LE. CCT change was 27.58 µm increase in RE and 27.23 µm increase in LE. After instillation of 4 µl of 0.1% fluorescein the mean increase in TCT and CCT were 30.09 and 30.26 µm for OD and 28.33 and 30.15 µm for OS respectively. Comparison between the post instillation of 2 and 4 µl measurements showed no significant differences. Conclusion: Combining a dual-Scheimpflug camera and 0.1% fluorescein may serve as a method to assess the pre-corneal tear film.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3