Analysis on characteristics of ground vibration induced by underground high-speed trains based on in-situ test

Author:

Dai Feng1ORCID,Yang Jizhong1,Bi Lanxiao2,Liu Yutao3

Affiliation:

1. China Railway Eryuan Engineering Group Co., Ltd, Chengdu, China

2. China Railway No. 10 Engineering Group Co., Ltd, Jinan, China

3. China Academy of Railway Sciences (Shenzhen) Research and Design Institute Co., Ltd, Shenzhen, China

Abstract

With the increasingly emerging traffic intersection form of high-speed railways passing underneath integrated transport terminals, the ground vibration induced by trains running on underground high-speed railways has attracted extensive attention. In combination with the engineering example of a high-speed railway in construction passing underneath an airport, the wheel-drop impact test in the high-speed railway tunnel was designed to obtain the vibration characteristics of surrounding soil. The vehicle-track-tunnel-ground semi-analytical three-dimensional model was established to determine the initial dynamic load condition of the vehicle loads. The amplitude-frequency characteristic and transmission law of the ground vibration induced by trains running on underground high-speed railways were predicted and analyzed. The influences of different operation conditions, track parameters, and tunnel burial depths were compared. The research results show that the ground vibration obtained through the wheel-drop test is greatly attenuated within 10 m from the track centerline, with an attenuation rate up to 70%. The vertical vibration amplitude is obviously larger than that of the other two directions. The lateral ground vibration amplitude is the smallest with the slowest vibration attenuation speed. When the high-speed train passes through at the speed of 350 km/h, the vertical and lateral vibration levels of the ground surface within 80 m range are 20∼80 dB and 43∼72 dB, respectively. The maximum attenuation coefficient of Z-vibration level reaches 0.276 dB/m. For each increase of 50 km/h of the train speed, the Z-vibration level of the ground increases by about 2 dB. The smaller fastener stiffness leads to the greater ground vibration within 20∼50 Hz. The ground vibration level is positively correlated with the fastener stiffness above 79 Hz. When the burial depth of the tunnel is greater than 14 m, the burial depth of the tunnel has little effect on the change of the Z-vibration level of the ground.

Funder

The Key R&D Project of Sichuan Province

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3