The Efficacy of Silver-Ion Implanted Catheters in Reducing Peritoneal Dialysis-Related Infections

Author:

Crabtree John H.1,Burchette Raoul J.2,Siddiqi Rukhsana A.3,Huen Isan T.1,Hadnott Linda L3,Fishman Arnold1

Affiliation:

1. Department of Surgery, Department of Medicine, Southern California Permanente Medical Group, Kaiser Permanente Bellflower Medical Center, Bellflower

2. Research and Evaluation Department, Kaiser Permanente Southern California, Pasadena, California, USA

3. Division of Nephrology, Department of Medicine, Southern California Permanente Medical Group, Kaiser Permanente Bellflower Medical Center, Bellflower

Abstract

♦ Background Dialysis-related infections are the commonest cause of catheter loss and transfer to hemodialysis. Surface modifications of the catheter that reduce infections are of major importance. ♦ Objective The efficacy of silver-ion treated catheters in reducing dialysis-related infections was tested. ♦ Methods The study design was a prospective, randomized controlled trial. Patients were implanted with either a silver-treated study catheter or a control catheter. Prospective collection of data included infectious complications and catheter survival. ♦ Results The subject groups were comprised of 67 silver-treated catheters and 72 control catheters. Demographic characteristics of the study and control groups were equal. Exit-site infection rates for the study group and control group (0.52 and 0.45 episodes/patient-year of dialysis respectively) were not different by Poisson regression analysis ( p > 0.4). Peritonitis rates were identical for the two groups (0.37 episodes/patient-year) and were not different by Poisson analysis ( p > 0.9). Antibiotic-free intervals between infections for the study and control groups were not significantly different for exit-site infections ( p = 0.58), peritonitis ( p = 0.44), or both infections combined ( p = 0.47). Actuarial analyses showed no differences between the groups in the probability of remaining free of exit-site infection ( p> 0.2) or peritonitis ( p > 0.7). Similarly, catheter survival was not significantly different between the groups ( p > 0.6). ♦ Conclusion Surface modification of catheters with ion beam implantation of silver produced no clinical effect with respect to reducing dialysis-related infections.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3