Intraoperative Hydroxyethyl Starch and its Effects on Different Fibrinogen Measurements

Author:

Winstedt Dag12,Solomon Cristina345,Hillarp Andreas26,Lundahl Tom26,Schött Ulf12

Affiliation:

1. Department of Anaesthesia and Intensive Care, Skåne University Hospital Lund, Lund, Sweden

2. Division of Anaesthesia and Intensive Care, Department of Clinical Sciences, Lund University, Lund, Sweden

3. Department of Anaesthesiology, Perioperative Medicine and General Intensive Care, Paracelsus Medical University, Salzburg, Austria

4. CSL Behring, Marburg, Germany

5. Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Centre, Vienna, Austria

6. Clinical Chemistry and Transfusion Medicine, Halland County Hospital, Sweden

Abstract

Background: Intravenous fluids with synthetic colloids such as hydroxyethyl starch (HES) are known to interfere with plasma fibrinogen concentration measurements. The aim of this study was to evaluate the effects of an HES solution on fibrinogen measurements in a clinical setting. Methods: The study was performed in patients who received at least 1 L of HES during intracranial tumor resection surgery. Blood samples were drawn before the start of surgery (baseline), after infusion of 1 L of HES, and at later time points. The fibrinogen concentration was measured using 3 different methods: (a) enzyme-linked immunosorbent assay (ELISA), (b) Clauss method with a photometric readout, and (c) Clauss method with an electromechanical readout. In addition, the fibrin-based clot quality was evaluated with the thromboelastometric FIBTEM test. Results: Forty patients were enrolled, and 25 patients were included in the analysis. The fibrinogen concentrations at baseline were 2.2, 2.3, and 2.6 g/L and after 1 L of HES 1.6, 1.7, and 1.9 g/L as measured by ELISA, the photometric test, and the electromechanical test, respectively. The electromechanical Clauss test measured significantly higher concentrations at these time points. The relative decrease, however, was comparable between methods (31%, 29%, and 25%, respectively) but significantly lower than the 44% relative decrease with FIBTEM maximum clot firmness. Conclusion: Despite providing different fibrinogen concentration values at baseline, the relative decrease in fibrinogen concentration after HES infusion was comparable among the 3 tests. In contrast, fibrin-based clot quality was more affected than fibrinogen concentration tests by HES infusion.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3