Treatment of giant intracranial aneurysms using the Pipeline flow-diverting stent: Long-term results from the International Retrospective Study of the Pipeline Embolization Device (IntrePED) study

Author:

Grandhi Ramesh1ORCID,Ravindra Vijay M.12ORCID,Kallmes David F.3ORCID,Lopes Demetrius4,Hanel Ricardo A.5ORCID,Lylyk Pedro6

Affiliation:

1. Department of Neurosurgery, Clinical Neurosciences Center, University of Utah, Salt Lake City, Utah, USA

2. Department of Neurosurgery, University of California San Diego, La Jolla, California, USA

3. Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA

4. Department of Neurosurgery, Advocate Health, Park Ridge, Illinois, USA

5. Lyerly Neurosurgery, Baptist Neurological Institute, Baptist Medical Center, Jacksonville, Florida, USA

6. Department of Interventional Neuroradiology and Neurosurgery, Instituto Medico ENERI – Clínica La Sagrada Familia, Buenos Aires, CABA, Argentina

Abstract

Background Traditional endovascular treatments of giant intracranial aneurysms are associated with high rates of complications and retreatment. Our objective was to examine the safety and long-term efficacy of the Pipeline Embolization Device for treatment of these aneurysms. Methods This retrospective study using the IntrePED database included all patients with giant intracranial aneurysms treated with the Pipeline device between July 2008 and February 2013. Efficacy outcomes were stratified by using the Raymond-Roy Occlusion Classification. Predefined safety outcomes included spontaneous rupture of the target aneurysm; ipsilateral intracranial hemorrhage; ischemic stroke; parent artery stenosis; and sustained cranial neuropathy. Results Sixty-six embolizations were performed to treat 63 giant intracranial aneurysms (including 2 ruptured): 49 (77.8%) in the anterior and 14 (22.2%) in the posterior circulation. The median follow-up was 22.4 (0.1–60.5) months. Class I angiographic occlusion was achieved in 72.0% (36/50). The neurological morbidity/mortality rate was 23.8% (15/63), with higher rates in the posterior circulation than in the anterior circulation (22.4% vs. 28.6%). Among seven deaths, five had neurological causes. The procedure-related neurological morbidity and mortality rates were 22.7% (15/66) and 7.6% (5/66), respectively. The spontaneous rupture rate was 4.5% (3/66). Two spontaneous ruptures (1 death), 4/4 postprocedural intracranial hemorrhages, and 6/9 ischemic events occurred within 30 days. In-stent stenosis and new-onset cranial neuropathy were not observed during the angiographic follow-up period. Conclusions Although procedure-related neurological morbidity/mortality rates were not insignificant, this study confirms the feasibility and long-term efficacy of the Pipeline Embolization Device to treat giant intracranial aneurysms.

Funder

Medtronic

Publisher

SAGE Publications

Subject

Immunology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3