Cardiac MRI in patients with cardiac pacemakers: practical methods for reducing susceptibility artifacts and optimizing image quality

Author:

Kaasalainen Touko12,Kivistö Sari1,Holmström Miia1,Peltonen Juha13,Pakarinen Sami4,Hänninen Helena4,Sipilä Outi1

Affiliation:

1. HUS Medical Imaging Center, Radiology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland

2. Department of Physics, University of Helsinki, Helsinki, Finland

3. Department of Biomedical Engineering and Computational Science, School of Science, Aalto University, Helsinki, Finland

4. Heart and Lung Center, Division of Cardiology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland

Abstract

Background Magnetic resonance imaging (MRI) of pacemaker patients has become available despite of previous contraindications. However, pacing systems containing ferromagnetic material may hamper the diagnostic quality of cardiac MR (CMR) images. Purpose To study methods for reducing susceptibility-based artifacts in CMR examinations of pacemaker patients. Material and Methods Altogether 16 patients were scanned with 1.5T MRI scanner using cine balanced steady-state free-precession (bSSFP) and spoiled gradient echo (SPGR) sequences. The use of frequency-scout was also evaluated. For myocardial late gadolinium-enhanced (LGE) imaging, SPGR or bSSFP readout inversion-recovery prepared gradient echo sequences were used with and without phase-sensitive inversion-recovery (PSIR). Two radiologists subjectively compared the image quality (IQ) and the ranges of susceptibility artifacts were evaluated objectively. Results The IQ proved adequate for diagnosing each patient, although in a few patients with a left-side implanted generator, artifacts hampered IQ in the anterior and anteroseptal segments of the myocardium in bSSFP cine and LGE sequences. In bSSFP cine, the use of frequency-scout could often transfer the banding artifacts away from the left ventricular myocardium. In LGE imaging, the artifacts were more pronounced in IR-bSSFP and PSIR than in IR-SPGR sequences. The ranges of generator-based artifacts were greater in bSSFP (10–12 cm) than in SPGR (6 cm) sequences due to banding artifacts. Conclusion The artifacts caused by pacemakers typically did not compromise the diagnostic IQ. The use of frequency-scout prior to bSSFP cine or the use of SPGR-based sequences could also improve IQ.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology