Revised Swedish guidelines on intravenous iodine contrast medium-induced acute kidney injury 2022: A summary

Author:

Nyman Ulf1ORCID,Brismar Torkel23ORCID,Carlqvist Jeanette4ORCID,Hellström Mikael4ORCID,Lindblom Maria5,Lidén Mats6,Liss Per7,Sterner Gunnar8,Wikner Franciska9,Leander Peter1ORCID

Affiliation:

1. Department of Translational Medicine, Division of Medical Radiology, University of Lund, Malmö, Sweden

2. Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institute/Karolinska University Hospital, Stockholm, Sweden

3. Department of Radiology, Karolinska University Hospital in Huddinge, Stockholm, Sweden

4. Department of Radiology, Institute of Clinical Sciences, the Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden

5. Department of Radiology, Linköping University Hospital, Linköping, Sweden

6. Department of Radiology, Faculty of Medicine and Health, Örebro University, Örebro, Sweden

7. Department of Surgical Sciences, Section of Radiology, Uppsala University, Uppsala, Sweden

8. Department of Nephrology, Skåne University Hospital, Malmö, Sweden

9. Department of Radiology, Umeå University Hospital, Umeå, Sweden

Abstract

The Swedish Society of Uroradiology has revised their computed tomography (CT) guidelines regarding iodine contrast media-induced acute kidney injury (CI-AKI). They are more cautious compared to the European Society of Urogenital Radiology and the American College of Radiology since the actual risk of CI-AKI remains uncertain in patients with moderate to severe kidney damage due to a lack of prospective controlled studies and mainly based on retrospective propensity score-matched studies with low-grade evidence. Another source of uncertainty is the imprecision of glomerular filtration rate (GFR) estimating equations. However, randomized hydration studies indictae an upper limit risk of CI-AKI of about 5% for outpatients with a GFR in the range of 30–44 or 45–59 mL/min/1.73m2 combined with multiple risk factors. Apart from GFR limits, the guideline also includes limits for systemic contrast medium exposure expressed in gram-iodine/GFR ratio.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3