Hepatic enhancement at computed tomography: is there a dependence on body weight past institutional contrast dosing limits?

Author:

Kesen Savas12ORCID,Svensson Anders13ORCID,Thor Daniel4ORCID,Brismar Torkel B.13

Affiliation:

1. Division of Radiology, Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden

2. Department of Radiology, Södersjukhuset, Stockholm, Sweden

3. Department of Radiology, Imaging and Physiology, Karolinska University Hospital, Stockholm, Sweden

4. Medical Radiation Physics and Nuclear Medicine, Imaging and Physiology, Karolinska University Hospital, Stockholm, Sweden

Abstract

Background Although described in product monographs, the maximum contrast media (CM) dose at computed tomography (CT) varies among institutions. Purpose To investigate whether an upper limit of 40 g of iodine in women and 50 g in men is sufficient or if there is a body weight (BW) dependence of mean hepatic enhancement (MHE) beyond those thresholds. Material and Methods At our institution, CM injection duration is fixed to 30 s and dosed 600 mg iodine/kg up to 40 g in women and 50 g in men. Pre- and post-contrast hepatic attenuation values (HU) were retrospectively obtained in 200 women and 200 men with glomerular filtration rate >45 mL/min undergoing 18-flurodeoxyglucose PET-CT (18F-FDG PET-CT) of which half weighed below and half above those dose thresholds using iodixanol 320 mg iodine/mL or iomeprol 400 mg iodine/mL. The correlation between BW and MHE was assessed by simple linear regression. Results Weight range was 41–120 kg in women and 47–137 kg in men. There was no significant relationship between MHE and BW in women receiving <40 g (r = −0.05, P = 0.63) or in men receiving <50 g (r = 0.18, P = 0.07). Above those thresholds there was an inverse relationship (r = −0.64, P<0.001 in women and r = −0.30, P<0.002 in men). There was no apparent upper limit where the dependence of hepatic MHE on BW decreased. Hepatosteatosis limited MHE. Conclusion Adjusting CM to BW diminishes the dependence of MHE on BW. There was no apparent upper limit for the relationship between BW and MHE in heavier patients at CM-enhanced CT.

Funder

Stockholms Läns Landsting

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3