Diagnostic value of conventional ultrasound and shear wave elastography in detecting transjugular intrahepatic portosystemic shunt dysfunction

Author:

Han Hao1,Yang Jian2,Jin Wei-kui2,Li Xia2,Zhang Feng3,Zhuge Yu-zheng3,Wu Min2,Yang Bin4ORCID

Affiliation:

1. Department of Ultrasound, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Nanjing, PR China

2. Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China

3. Department of Gastroenterology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China

4. Department of Ultrasound, Jinling Hospital, Nanjing Medical University, Nanjing, PR China

Abstract

Background Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction can cause recurrent portal hypertension (PH)-related complications such as ascites and gastroesophageal variceal bleeding. Portography is invasive and costly limits its use as a screening modality. Purpose To assess the clinical value of conventional ultrasound in combination with point shear wave elastography (pSWE) to predict TIPS dysfunction. Material and Methods A total of 184 patients with cirrhosis scheduled for TIPS implantation were enrolled in this study and evaluated retrospectively. The splenoportal venous blood flow parameter, liver stiffness (LS), and spleen stiffness (SPS) were measured. Outcome measures included differences in portal vein velocity (PVV), splenic vein velocity (SPVV), LS, and SPS. The accuracy of change in PVV (ΔPVV), SPVV (ΔSPVV), and SPS (ΔSPS) to diagnose TIPS dysfunction was investigated. Results TIPS dysfunction occurred in 28 of 184 patients (15.2%). Eighteen (64.3%) patients had shunt stenoses and 10 (35.7%) had shunt occlusion. Portal vein diameter (PVD), PVV, splenic vein diameter (SPVD), SPVV, LS, and SPS were not significantly different between the TIPS normal and TIPS dysfunction groups. Compared with the TIPS normal group, PVV and SPVV of the TIPS dysfunction group decreased significantly, whereas SPS increased significantly ( P < 0.001). The values of areas under the receiver operating characteristic curves of ΔPVV, ΔSPVV, and ΔSPS for the diagnosis of TIPS dysfunction were 0.97, 0.96, and 0.87, respectively. Conclusion pSWE showed a diagnostic efficacy comparable to conventional ultrasound for diagnosing TIPS dysfunction and can be used routinely after TIPS procedures.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3