Quantification of cardiac iron in patients with thalassemia with 3-T MRI calibrated by 1.5-T MRI

Author:

Xu Fengming12,Luo Chaotian12,Li Meicheng12,Guan Kaiming12,Peng Fei12,Yang Gaohui23,Peng Peng12ORCID

Affiliation:

1. Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, PR China

2. NHC Key Laboratory of Thalassemia Medicine (Guangxi Medical University), Nanning, Guangxi Zhuang Autonomous Region, PR China

3. Department of Hematology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, PR China

Abstract

Background Due to the small sample size of many studies, it remained unclear what standardized reference range the T2* cutoff at 3 T would be used to assess the severity of cardiac iron load. In addition, the number of patients with moderate to severe cardiac iron load was small in some studies, especially the sample of patients with severe cardiac iron load. Purpose To explore the feasibility, reproducibility, and reliability of using T2* values in quantifying cardiac iron load in patients with thalassemia at 3 T. Material and Methods A total of 122 patients with thalassemia underwent cardiac T2* imaging at both 1.5 T and 3 T. Cardiac R2* (1000/T2*) values of the 100 patients at 3 T were fitted against the values at 1.5 T using linear regression and the prediction equation was derived. The remaining 22 cases were used to test the prediction accuracy of the equation. Results The combined R2* values exhibited a strong linear relationship between 1.5 T and 3 T ( r = 0.830, P<0.001). At the center, it had a slope of 1.348 and an intercept of 37.279. According to the equation, the truncated T2* values of cardiac iron overload and cardiac heavy iron overload at 3 T were <10 ms and <6 ms, respectively. The two truncated T2* values were used to diagnose different levels of cardiac iron overloaded of 22 patients at 3 T; the accuracy rates were 95.5% and 100.0%, respectively. Conclusion T2* quantification of cardiac iron load at 3 T MRI resulted to be feasible, reproducible, and reliable.

Funder

National Natural Science Foundation of China

NHC Key Laboratory of Thalassemia Medicine

Innovation Project of Guangxi Graduate Education

Publisher

SAGE Publications

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3