Three-dimensional proton magnetic resonance spectroscopic imaging with and without an endorectal coil: a prostate phantom study

Author:

Ma Chao1,Chen Luguang1,Scheenen Tom WJ2,Lu Jianping1,Wang Jian1

Affiliation:

1. Department of Radiology, Changhai Hospital of Shanghai, the Second Military Medical University, Shanghai, PR China

2. Department of Radiology, Radboud University Medical Centre, Nijmegen, Gelderland, The Netherlands

Abstract

Background Proton magnetic resonance spectroscopic imaging (MRSI) of the prostate has been used with only a combination of external surface coils. The quality of spectral fitting of the (choline + creatine)/citrate ([Cho + Cr]/Cit) ratio at different field strengths and different coils is important for quantitative/semi-quantitative diagnosis of prostate cancer. Purpose To evaluate the quality of spectral fitting of the (Cho + Cr)/Cit ratio of a prostate phantom using MRSI at different field strengths and various coils. Material and Methods Experiments were using 1.5-T and 3.0-T MR systems. Measurements were taken on a homemade prostate phantom with different coils: spinal array; abdominal array; and endorectal. The signal-to-noise ratio (SNR) of choline, creatine, and citrate peaks as well as the (Cho + Cr)/Cit ratio in each voxel were compared among groups using multi-way analysis of variance. Results Magnetic field strength, coils, and plane position had a significant effect on the SNR or (Cho + Cr)/Cit ratio, and there were interactions among groups (all P = 0.000). The 1.5-T (0.228 ± 0.044) exhibited a higher (Cho + Cr)/Cit ratio than the 3.0-T (0.125 ± 0.041) magnetic field strength (F = 3238, P = 0.000). The (Cho + Cr)/Cit ratio of both surface coils (0.183 ± 0.065) and all coils (0.181 ± 0.057) was significantly lower than that of the endorectal coil (0.195 ± 0.077) (both P < 0.05), but significant differences in the mean (Cho + Cr)/Cit ratio were not observed if surface coils and all coils were used ( P > 0.05). No significant differences were found among the (Cho + Cr)/Cit ratios of all voxels in the middle planes by the post-hoc analyses (all P > 0.05). Conclusion Three-dimensional proton MRSI of prostate metabolites in a phantom using surface coils is feasible and reliable, but (Cho + Cr)/Cit ratios acquired at different magnetic fields and coils were different. This difference should be taken into account when calculating this ratio in a field strength-independent way.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3