Consequences of Progressive Full-Thickness Focal Chondral Defects Involving the Medial and Lateral Femoral Condyles After Meniscectomy: A Biomechanical Study Using a Goat Model

Author:

Koh Jason L.1,Jacob Kevin C.2,Kulkarni Rohan2,Vasilion Zachary1,Amirouche Farid M.L.12

Affiliation:

1. Department of Orthopaedic Surgery, Orthopaedic and Spine Institute, NorthShore University HealthSystem, Evanston, Illinois, USA.

2. Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois, USA.

Abstract

Background: Full-thickness chondral defects alter tibiofemoral joint homeostasis and, if left untreated, have the potential to progress to osteoarthritis. Purpose: To assess the effects of isolated and dual full-thickness chondral defect size and location on the biomechanical properties of the lateral femoral condyle (LFC) and medial femoral condyle (MFC) during dynamic knee flexion in goat knees without menisci. Methods: In 12 goat knees, we created progressively increasing full-thickness circular chondral defects (3-, 5-, and 7.5-mm diameter) in the weightbearing contact area of flexion and extension in the MFC, the LFC, or both. Each knee was fixed into a custom steel frame and attached to a motor with sensors inserted intra-articularly. For each testing condition, the knee was loaded to 100 N and underwent a dynamic range of motion between 90° of flexion and 30° of extension. The following parameters were collected: contact area, contact pressure, contact force, peak area, and peak pressure. Study Design: Controlled laboratory study. Results: The peak pressure at the defect rim of the MFC at full extension increased by 51.51% from no defect (1.887 MPa) to a 7.5-mm defect (2.859 MPa) ( P < .001), and the peak pressure at the defect rim of the LFC at full extension increased by 139.14% from no defect (1.704 MPa) to a 7.5-mm defect (4.075 MPa) ( P < .001). The peak pressures for LFC defects at all 3 diameters were significantly greater when compared with dual defects consisting of increasing LFC defect diameter and constant MFC defect diameter ( P < .001 for all). Conclusion: Extremely large increases in peak pressure were seen at the rim of articular cartilage defects when evaluated under dynamic loading conditions. Isolated LFC defects experienced a greater increase in defect rim stress concentrations when compared with isolated MFC defects for equivalent increases in defect size. Defect size played a significant role independent of location for peak pressures on the MFC and LFC. Clinical Relevance: Significant rim-loading effects increase with defect size under dynamic loading and may result in increasingly rapid progression of articular cartilage lesions. Within the context of this goat model, findings suggest that lateral compartment chondral lesions are more likely to progress than medial compartment lesions of equivalent size.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3