FiberWire vs FiberTape: Comparison of Bacterial Adherence in a Murine Air Pouch Wound Model

Author:

Blumenthal Allison M.1,Bou-akl Therese1,Rossi Mario D.1,Wu Bin1,Ren Wei-Ping2,Markel David C.1

Affiliation:

1. Ascension Providence Health System, Southfield, Michigan, USA.

2. Wayne State University, Detroit, Michigan, USA.

Abstract

Background: For high–tensile strength sutures, past research has largely focused on mechanical properties or bacterial adherence across various manufacturers. Purpose: This study investigated high-tensile strength sutures with different shapes but otherwise identical composition. The purpose was to evaluate the differences between high–tensile strength suture wire and suture tape relative to bacterial adherence and bacterial retention after washout. Study Design: Controlled laboratory study. Methods: Sutures were implanted in dorsal air pouches of 72 BALB/cJ mice. Experimental pouches were inoculated with Staphylococcus aureus; no bacteria were used in the control conditions. The mice were randomized into 3 groups: group 1 underwent suture extraction 7 days after implantation; group 2 underwent an irrigation procedure, followed by immediate suture extraction on day 7; and group 3 underwent an irrigation procedure on day 7, with delayed suture extraction on day 14 after implantation. The sutures were evaluated using confocal microscopy; electron microscopy; and spectrophotometry, through which optical density, as measured by the amount of scattered light, is directly correlated with the number of bacteria. Histological assessment was performed on the pouches. Results: Optical density (mean ± SD) was significantly higher for FiberTape sutures than for FiberWire sutures, respectively, at the 2-hour time point for all groups (group 1, 0.0550 ± 0.0081 vs 0.0162 ± 0.006 [ P = .0054]; group 2, 0.0225 ± 0.0049 vs 0.0056 ± 0.0006 [ P = .0045]; group 3, 0.055 ± 0.0222 vs 0.0043 ± 0.0005 [ P = .0103]). Additionally, groups 2 and 3 showed statistically significant results at the 4-hour time points (group 2, 0.0384 ± 0.0087 vs 0.0145 ± 0.0042 [ P = .0280]; group 3, 0.0532 ± 0.0159 vs 0.0101 ± 0.0025 [ P = .0058]). The wash fluid also demonstrated significantly greater optical density for the FiberTape than the FiberWire sutures, respectively, at the 2-hour time point for all groups (group 1, 0.1657 ± 0.0319 vs 0.0317 ± 0.008 [ P = .0063]; group 2, 0.0522 ± 0.0156 vs 0.0127 ± 0.0022 [ P = .0219]; group 3, 0.1707 ± 0.0205 vs 0.0191 ± 0.0053 [ P < .0001]). No bacterial growth occurred in the control conditions. Histological assessment revealed only mild inflammation in the control groups as compared with more severe responses in the experimental groups at all time points. Conclusion: FiberTape was associated with increased bacterial adhesion as well as retention as compared with FiberWire in an in vivo murine wound model. Clinical Relevance: This study demonstrates that suture design influences the occurrence of and ability to clear surgical infection and must be considered when selecting high-tensile strength sutures in a clinical setting.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3