Stabilization and Gap Formation of Adjustable Versus Fixed Primary ACL Repair With Internal Brace: An in Vitro Full-Construct Biomechanical Cadaveric Study

Author:

Bachmaier Samuel1,Smith Patrick A.2,Hammoud Sommer3,Ritter Daniel1,Hauck Oliver1,Wijdicks Coen A.1

Affiliation:

1. Arthrex Department of Orthopedic Research, Munich, Germany

2. Columbia Orthopaedic Group, Columbia, Missouri, USA

3. Rothman Orthopaedic Institute, Philadelphia, Pennsylvania, USA

Abstract

Background: A knotless, tensionable primary anterior cruciate ligament (ACL) repair system preloaded with an internal brace has been released. Currently, there is no biomechanical data on the stabilization and gap formation behavior of the adjustable system when compared with fixed repairs in human ACL tissue. Hypothesis: That knotless adjustable suture repair with an internal brace would provide overall higher construct stability and greater load share on the ACL with less gap formation compared with fixed repair. Study Design: Controlled laboratory study. Methods: Human cadaveric knees were utilized for internal braced ACL repair constructs (each group n = 16). Two fixed groups consisting of a single-cinch loop (SCL), cortical button (SCL group), and knotless suture-anchor (anchor group) were compared with an SCL-adjustable loop device (SCL-ALD) group. Testing was performed at 4 different peak loads (50, 150, 250, 350 N) over 4000 cycles at 0.75 Hz including suture repair preconditioning (10 cycles at 0.5 Hz) for SCL-ALD. Specimens were ultimately pulled to failure with a cut internal brace. The final loading situation of the construct and ACL repair with gap formation and ultimate strength were evaluated. Results: Peak elongation at various peak loads showed a significantly higher ( P < .001) stabilization of SCL-ALD when compared with both fixed groups. There was a significantly higher ( P < .001) load share of SCL-ALD, especially at lower loads (48% of 50 N), and the gap formation remained restricted up to 250 N. With only a little load share on the fixed constructs (<6%) at lower loads (50, 150 N), gap formation in these groups started at a load of 150 N, leading to significantly higher gaps ( P < .001). The ultimate failure load for SCL-ALD and anchor groups was significantly increased ( P < .001) as compared with SCL. The stiffness of SCL-ALD (62.9 ± 10.6 N/mm) was significantly increased ( P < .001). Conclusion: Internal braced knotless adjustable fixation for ACL repair with preconditioning of the suture repaired ligament increased the overall stabilization with higher load share on the ACL and restricted gap formation (<0.5 mm up to 350 N) compared with fixed suture repair. All internal braced repairs restored stability according to native ACL function. Clinical Relevance: Adjustable ACL repair improved the mechanical characteristics and reduced gap formation, but the overall clinical significance on healing remains unclear.

Funder

Arthrex

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3